Laserfiche WebLink
TO: <br />PROM: <br />PUBL/C WORAfS <br />MEMORANDUM <br />Ryan Hitt, Burgess Weaver Design Group <br />Paul McKee EngincerinEJPubiic Services Depactment <br />DATE: May 21, 2003 <br />SUB.TCCT: Pour Comers Everett Re�1i1 <br />PROPOSAL: Parking Lot <br />LOCATION: 8130 Evergreen Way <br />A review of this project by the Engineering/Public Serviccs Depa�iment indicates that ��e following <br />corrections should be made: <br />Sheet CO of 5 — <br />a. Add note regarding leak tcst etc. (see below) to plan. <br />b. Add note defining conshuction sequcnce - Pxample: <br />i. Preconstuction wnferencc with city Public Works Inspector <br />ii. Install Erosion Controls <br />iii. Clear and Grade <br />iv. Install Utilities <br />v. Complete Project <br />vi. Remove Erosion Controls <br />vii. Submit As Built Pla�u <br />2. Sheet C2 of 5— <br />a. n'o Comment <br />3. Shcet C2 of 5— <br />a. The 6 foot high polyvinyl coated chain link fence is required to encompass lhe entire perimetcr <br />of the pond �a. It should bc extended across Oie north side of the pand adjacen[ lo the <br />parking stalls, leaving a sp�ce of 2.5 feet clear L� the curb to allow for bumper overhang. <br />b. Detail 1 on lhis sheet shall cefer to City of Evereti Standard Plan #307. <br />4. Sheet C3 of 5— <br />a. The stoim drainage outfall from the pond intersecis an existing City of Lverelt Water Main. <br />There is a potential contlict at the crossing point. The water main should be "pot holed" to <br />detcmune its depth prior to finalization oFthe plans. If the water mtin necds to be adjusted, lhe <br />work must be performed F,y City of Everett personnel at the developer's expense. <br />5. Sheet C4 of 5— <br />a. In Detail 2 Section A A— The wetpond �vater surFace ei;vation is listed as `372.00' it should <br />be `572.00'. <br />b. In Detail 3 Section &B — The wetpond waler surface elevation is listed as `372.00' it should <br />be `572.00'. <br />c. In Detail 3 Section SB —1'he bottom of the wetpond clevation is listed as `3G8.50' it should <br />be `568.50'. <br />