Laserfiche WebLink
Mar 29 2007 3:3GPM HBfl#Design#Group 4252522826 p.8 <br />32. Pfle� l6 ISsuanCe of a cerl�fcate of occuPancy, a maintenance and monitoring security i� the amount of <br />$8,190. This security shall be pruvided (or a period of five years from the date of completi�n of the <br />certification of compietion of the enhancement work. <br />33. Prior to issuance of a bulding permit, the appiicant shall provide e critica! area covenant to ensure <br />protection of the welland, stream and buffer areas. <br />34. A Knox Box (s required. <br />35. Fire tanes shall be pravided as required fn Everett Municipal Code 46.44. Fire lanes shall be identified <br />by red curbs with white stenciling sYoting "NO PARKING - FIRE LANE" and vertical signs stating'NO <br />PARKING - FIRE LANE - 70W AWAY ZONE" Location shall be approved 6y the Fire Marshal. <br />36. Premises shall he clearly identified by the correct address at the street entry. Buildings shall be cleariy <br />idenfified so as to be visible and legi6le irom the access road. I�div[dual apartrnents and builes, where <br />applicable, shall be clearly end legibly ideniified from the access road. <br />37. Flre hydrant locations as planned are acceptable. <br />38. Premise identifiqtion and all required fire deparfment aocess roads and fire hydrants shall be in s�rvice <br />priot to commencement ot construction. <br />39. Based upon 23,500 square feet of Type IIB, sprinkie�ed conslructlon, the fire fiaw reauirement is 1,625 <br />gpra: <br />40. A portable fire extinguisher with a minimum U.L. ratiny ai 2-A:10-B:C shal! be provlded withfn 75 feet of <br />lravel on all 1loors of each 6uildirg during consruction and prior to occupancy. <br />41, An approved automatic fire detection system shall be provided as required by City Ordinance No. 1902- <br />92, Chapter i6.76, of the Everett Municipal Code. <br />Plans for such system shall be submitted lo the Fire Mersha! forreview ard appro�al priorlo hstallation. <br />Submittal shall inciude cut sheets of all equipment in9ended for use. Appropriate trip tests, wilnessed by <br />a Fire Department Insoector, shall 6e pertormed, along with a certificate of corcoletion, prior to final <br />aaeptance of the system. <br />Fi�e elami systems shall i�e installed according to NFPA Standard 72. InstaNation of fire alacm <br />components, incfuding basic wiring, may not commence before ptans aze approved by the Fre <br />Department plan Reviewer. Fire alarm drawings must be professionally rendered, in sufficient detail, <br />and must be internaliy consistent. Riser diagrarns must match installation plans and load calculations. <br />Components must be listed and approved for use togeiher. Changes to plans must Inciude iew <br />drawings and plculations and must be approved by lfie Fire Departmeni Plan Revievoer priorto <br />installatic�. Fire alarm installation is subject ta field inspection 6y a Fire Departrnent Inspedor. An <br />approved set oF plans and the Building Department elecirical permil must be present For any inetalla6on <br />inspeclion. <br />Fire alarm systems shall 6e insla:led under permit of Ihe City of Everett Buifding Department. Electrical <br />inspactions and approval are *equired prior lo calling for acceptance lests. Call {425) 257-8810 for <br />pertnil inFormatfon. <br />The absence of �vorking phone lines for the alartn system will be cause for posiponing fire daparhttent <br />fnspection and festing and shall resuit In denfal of occupancy. <br />`d ��9 <br />