Laserfiche WebLink
Mar 29 2007 3:36PM HBF#Design#Group 4252522826 p.9 <br />' f <br />42. An approved automat(c suppression systern shell be provided as required by Cfty ordinance No. 1902- <br />92, CFapler 16.76, of the Everett PAunidpal Code. The syslem mu�t inck�do e mechanical watergong <br />hell. <br />Plans for any such system shall be submitted to the Buildir,g Department for examinaGon and epproval. <br />Such plar,s shall Include plans for the underground mains that will eupply the sprirrder system. <br />The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA 13, <br />NFPA 13R, or NFPA 13D eyatem depending upon several faclws. Sprinkler instaYaGon shall not begin <br />wifhout an approved and slampecl set of plans irom the Buildtng Department The Fire Departrnertl will <br />atso review the plans and shali field inspect the installaVon based mly on approved plans that must be <br />on sile. Changes to plans must be approved by both the Building and Fire DepaAmertts. <br />Aboveground sprinkter piping shall be hydrostatically tested as estnWished in NFPA Standard 13. ' <br />Underground piping shall be hydroslaHcally tested and flushed as established in NFPA Standard 24 for <br />pr'rvate fire mains. (Below-arcund ofpinq must be instelled bv Washinaton State Pahol Licerued <br />i)nderQround Sprinkler line certified "U" installers For turther informatfon, contad the State Flre <br />Marshal's Office at (360) 570�3134 or contact ihe Everett Flre DepaAment at (425) 257-8125). All such <br />tests shatl be wifiessed by a Fire Department inspectnr. Call (425) 257-8124 to make an appoinlment <br />forinspecGon. <br />Contractors' matarials and test certificates shall be su6mitted to the Everett Fire Department prior to <br />issuance of any Certiflcates oF Occupancy. <br />Call (425) 2SI-8125 for more infortnatian. <br />A3. Construction and demolitlon uf buildings shall ba (n compliancs with the provisions of the 2003 <br />Internalbnal Fire Code, Chapter'14. <br />44. Permits are required from the Fre Department for removal and instailation oi underground fuel tanka. <br />45. All fire alarm control panels (FACP) and sprinkier �alves shall be In heated rooms or closets with <br />standard man door access. Locations shall be approved by lhe Fire Marshal's Otfice. <br />Ii the men door access is not directly from the outside, then a PIV is required. An FDC is required, <br />location to be dete�mined by the F�e Marshal. A water motorgong is7equired,with the instaqaQon of an <br />NPPA �3 sy�tem. <br />46. Dumpsters over 1.5 cubic yards eapacity shall be tocaled a minimum oT 5 ieet from 1he buitding. <br />gd <br />