My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
215 SW EVERETT MALL WAY EVERETT POWER SPORTS 2018-01-02 MF Import
>
Address Records
>
SW EVERETT MALL WAY
>
215
>
EVERETT POWER SPORTS
>
215 SW EVERETT MALL WAY EVERETT POWER SPORTS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2023 9:15:55 AM
Creation date
2/10/2017 2:22:46 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
215
Tenant Name
EVERETT POWER SPORTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a) Double doors #9 should be shown as one -hour assemblies on the door <br />schedule. Section 302.3 <br />b) The occupancy separation walls should be labeled as such on the plans. <br />c) The occupancy separation walls are not continuous vertically. The <br />floor/ceiling assemblies between the upper and lower occupancy <br />separation walls is also an occupancy separation and should be noted on <br />the plans. <br />d) The rated floor/ceiling assembly that is part of the occupancy separation <br />should be one of the listed assemblies shown in NER-200 or another <br />assembly from the UL Directory. <br />e) The walls/columns supporting the one -hour floor/ceiling assembly should <br />also be of one -hour construction. Details should be provided. Section <br />302.2 <br />f) Duct penetrations through the occupancy separation should be shown with <br />smoke/fire dampers. Sections 713.10 & 713.11 <br />5) The sprinkler room is not consistent with the size and location requirements noted <br />in Everett Standard 523 (attached). <br />6) Details for the removable guardrails should be provided. Calculations verifying <br />the loads required by Table 16-B should be included. Section 509 <br />7) Fire blocking should be shown at the intersection of interior walls and the <br />dropped ceiling (see detail 1/A7). Section 708.2.1 <br />8) The stairs that serve both stories should be shown with handrails that extend a <br />minimum of 23" beyond the bottom riser. Section 1003.3.3.6 <br />9) Two drinking fountains are required. One accessible, and the other mounted at <br />standard height. Sections 1105.4.1 & 2903.4.1 <br />Prepare a response letter showing where each item in this correction letter is addressed <br />on the plan set. <br />Upon submittal of the drawings, your application will be given priority and plan review <br />will recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to <br />ensure that the proposed structure will be constructed in compliance with all adopted <br />codes. <br />Sincerely, <br />e <br />Associate Engineer <br />0) <br />