Laserfiche WebLink
8. Temporary erosion control measures for construction activity must be operational prior <br /> to commencement of any clearing or earthwork. <br /> 9. This project must comply with d�e current City of Everott Building Code and Sprinkler <br /> Ordinance. <br /> 10. Special charges for connection to the sewer and water systems in accordance aith <br /> Ordinance 1998-94 and subsequent revis�ons are applicabie. These charges are based <br /> on projected water usage and can be substantial. The 4pplicant is encouraged to obtain <br /> a copy of the ordinance and determ�ne estimated charge� nrior to building permit <br /> application. The actual charges shall be computed by the Public Works Deparanent <br /> per the ordinance in effect at the time of building permit issuance. <br /> 11. When access to or within a structure or an area is unduly difficult because of secured <br /> openings or where immediate access is necessary for life saving or fire-fighting <br /> purposes, the Fire Department may recommend or require a key box to be installed in <br /> an accessible location. A rapid entry system may also be desirable in order to avoid <br /> unnecessary dar.�age while making entry to any building during an emergency situation. <br /> Please cali (435) 257-8123 for more information. <br /> 12. ptemise Identification - Premises shall be clearly identified by the correct ::ddress at the <br /> sveet entry. Buildings shall be clearly identified so as to be visible and legible from <br /> the access road. Individual a�artments and suites, where applicable, shall be clearly <br /> and legibly identified from the access road. <br /> 13. A fire hydrant is required within 200 feet driving distance, but not closer than 50 feet, <br /> of every structure. Location of the hydrant(s) shall be approved by the Fire Marshal. <br /> 14. Fire Flow - Fire flow requirements for this structure are 1500 gpm. <br /> 15. PorLble Fire Protertion - A portable fire extinguisher with a minimum U.L. rating of <br /> 2-A:10-B:C shall be provided within 75 feet of travel on all floors of the building <br /> during construction and prior to occupancy. <br /> 16. ara c - Install a portable fire extinguisher with a minimum U.L. rating of 2-A:40- <br /> B:C within 30 feet of travel distance of all portions of this building. <br /> 17. �ye,A]arm �yc�em - An approved automatic fire detection system shall be provided as <br /> requirc<t,by City Ordinance No. 1902-92, Chaprer 16.76, of the Everett Municipal <br /> Code. <br /> Plans for such system ;lfa:l.be submitted to the Fire Marshal for review and approval <br /> prior ro installation. Submirczkshall include cut sheets of all equipment intended for <br /> use. Appropriate trip tests, witnessr.d by a Fire Department inspector, shall be <br /> performed, along with a certificate of completion, prior to final acceptance of the <br /> system. <br /> Fire alarm systems shall be installed according to NFPR Standard 72. <br /> a <br />