, , ( �. <br /> ENG/NEER/NG / PUBL/C SERV/CES DEPARTMFNT <br /> Letter mailed dated January 23,2006 (amended by fax on January 26, 2006) <br /> Mr. Greg Gliege <br /> Project Services Corporation <br /> 16410-84th Street NE#D-188 <br /> Lake Stevens, WA 98258 <br /> Project: A.R.A. Collision <br /> Job Address: 10721 Evergreen Way <br /> Plan Review#: K0601•002 and B0601-013 <br /> Dear Mr. Gliege, <br /> In response to your application for wnstruction permit, your plans have been examined and you <br /> are advised that permits cannot be issued until the following issues aze clarified. These <br /> cottunents address building issues only Additional revisions or additions may be required by <br /> other d�partments (such as Utilities, Planning or Fire). All references refer to the 2003 <br /> International Building Code (IBC), as amended by the State of Washington and/or the <br /> Washington State Energy Code, 2003 edition, unless noted othenvise. <br /> In order for the processing your application to continue, it will be necessary to provide the <br /> Building Division with hvo scts of drawings reflecting thc correcHons requested. <br /> Construction <br /> `,"?� ' ' 1. Submitta!K0601-002: An automatic fire detection system is required throughout the <br /> � ' ` building,per City of Everett Ordinance 1902-92, Chapter 16, Section 76.030 end 76-060. <br /> Sprinkler layouts are required both above and below storage areas noted in plan above <br /> office ceilings, Section 903.2.8.1 (amended by fax on January 26, 1006). <br /> 2. Construction details for pit and support system of the canopies for the booths. <br /> Dimensione3 pla�� location of each preparation/finishing booth, and a dimensioned <br /> architectural section and/or elevation for each booth. <br /> , �i ,,,; r;_.. 3. Stamped and wet sealed certification by a licensed structural engineer that the existing <br /> structure(and modifications where needed)can support all new dead and live loads, with <br /> supporting calculations and modification details. <br /> � 4. Existing building height. With additional supporting infurmation, construction Type SB <br /> may be applicablc in lieu of Type SA noted on the submittal. <br /> i 5. Maximum quantities of health and physical hazard materials that will be stored and used <br /> on site,reference Table 414.2.4 for Group M and S occupancies. � <br /> n � � <br /> CITY OF EVERETT• 3200 Cedar Street• Everett,WA 98201 • (425) 257-8800• Fax(425)257-8856 ( „� <br /> B06UI-0IJ 10]]I Evagnm Wry.doc - . <br />