My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11102 EVERGREEN WAY 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
11102
>
11102 EVERGREEN WAY 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2018 7:37:56 AM
Creation date
2/10/2017 10:38:05 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
11102
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following standard review comments are included for the <br /> applicant�s interest. They may or may not be applicabla in <br /> � the next review depending upon the chanqes made in response <br /> ��to the above comments. The City's Design and Construction <br /> Standards should also be consulted for more qeneral design <br /> criteria. <br /> DETENTION CALCDLATIONS <br /> lPotoond/D�tention: <br /> A completed City of Everett Drainage Calculation Form musL <br /> be submitted, showing the required detention volume and the <br /> allowable release rate. <br /> � The stage-storage relationship of the pond must also be <br /> submitted to show that the pond has the capacity to store <br /> the required wetpond volume and the live detention volume. <br /> The design wetpond volume must be reached or exceeded for <br /> the 2 year, 24 (12)-hour storm. As a first guess, the <br /> primary orifice should be sized to release approximately the <br /> existinq 2 year storm peak and the second orifice located at <br /> the elevation relating to the design wetpond volume. The 2 <br /> year, 24 (12) -hour storm should then be routed through the <br /> pond to verify that the wetpond design volume is being <br /> reached or exceeded for the design storm. <br /> The maximum storage in the wetpond (dead storage + live <br /> storage) during the design storm (2 year, 12 (24) -hour storm) <br /> must be equal to or greater than the calculated required <br /> wetpond volume. The design storm must be routed through the <br /> pond to demonstrate that this requirement is being met, <br /> unless the entire required wetpond volume is being provided <br /> as dead storage. The minimum allowable orifice size in the <br /> City of Everett for this application is 1 inch. If this <br /> size orffice doesn't result in the required storage in the <br /> pond, then the percentage of the required wetpond volume <br /> provided as dead storage must be increased until the <br /> requirement is satisfied. <br /> The required volume of the wetponds must be determined <br /> separately from detention volume. The required wetpond <br /> volume is equal to the volume of runoff from the 2 year, <br /> 12 (24)-hour storm (1.20 (1.55) inches of precipitation) . Two <br /> methods are acceptable for determining the required wet pond <br /> volume; either multiply the area of impervious surface in <br /> the contributing basin by 1.20(1. 55) inches or determine the <br /> volume of the 2 year, 12 (24) -hour hydrograph for the entire <br /> contributing area. At least 50� of this volume is required <br /> to be permanent storage in the pond. The required detention ' <br /> volume must be provided as live storage in addition to the <br /> dead storage. <br />