Laserfiche WebLink
' ENVIRONMENTAL HEALTH DIVISION <br /> �� SNOHOMISH 3020 Rucker Avenue, Suite 104 <br /> HEALTH Everett, WA9820i-3900 <br /> DISTRICT 425.339.5250 FAX: 425.339.5254 <br /> Deaf/Hard of Hearing: 425.339.5252 (TTY) <br /> January 12, 2007 <br /> � �6�� -05�- <br /> Thomas Li <br /> 1G022 12 Avenue SW <br /> Burien, WA 98166 <br /> Subject: Proposed Zab Thai Restaurant, 11108 Evergreen Way, Everett <br /> Dear Mr. Li: <br /> Your revised plans (due to wall relocation) have been reviewed with the Rules and Re�ulations of the <br /> State Board of Health, and wiUi the policies of the Snohomish Health District. With the addition of the <br /> following conditions, die plans are approved. <br /> 1. The Health District operating permit application process must be completed prior ro opening for <br /> business. This facility will be a high risk restaurant with seats. <br /> 2. An indirect waste drain is required for the food prepazatian sinks, [hree-compartment sink, <br /> ntechanical dishwasher, ice machine, pop dispenser, running water dipper well, steam table, walk-in <br /> refrigeration, and any equipment in wliich food is placed. <br /> 3. A reduced pressure backflow preven[ion device is required at the end of the copper water pipe <br /> serving the pop dispensing sys[em prior to the carbona[ion device. No copper pipe or other <br /> potentially corrosive materiaf is allowed after the reduced pressure backflow prevention device. <br /> 4. Each food preparation sink must have at least one integral drainboard. <br /> 5. A horizontal separation of at least 1G inches or a vertical partition 16 inches in height is required <br /> between the vegetable preparation sink and raw meat/seafood preparation sink. <br /> 6. A horizontal separation of at least IG inches or a vertical partition 16 inches in height is required <br /> between the l�andwasU sinks and all food preparation areas. <br /> 7. A horizontal separation of at least 1G inches or a vertical partition 16 inches in height is required <br /> bet�veen thc handwash sink and the dishwasher. <br /> 3. Water heaters must be of sufficient size to provide hot water to dishwasher ancl/or scullery sinks and <br /> at t6e same time provide liot water to all h��d�vash sinks. <br /> 9. Hot water must be available to all handwash sinks within IS seconds. The liot water for the facilitv <br /> must not Ue used, at any piumbing fixture, for a minimum of 6 hours priar to the preoperational <br /> inspection. Tl�is is required so diat proper testing of tlie 1�-second time requirement for liot water <br /> availability can be completed. <br /> 10. All food sen�ice equipment, both new and used, must be fisted by the National Sunitatiar <br /> Fnundutron (NSP) or cyuivalent Cor its intended use. Used and new refrigeration must be capable af <br /> holding potentially Itazardous lood at �11°l� ur below. <br /> 1 l. Cxtra �vall protection is required on walls behind al] sinks, including res[room hand�vash sinks, and <br /> (ood preparation counters und tables. A 1G-incli liigl� backsplash of plastic laminate, fiberglass- <br /> reinlorced plastic or cqual is acceptable. A backsplash higher than lti inches is required on the �vall <br /> behind counter top equipment taller than I G inches. Ploor to ceiling protection is required on the wall <br /> Uehind disl�washers. 1'Vall protection behind mop sinks must cover the entire splash zone. Plastic <br /> coated hardboard is notacceptable. <br /> I I�, � <br />