My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11802 EVERGREEN WAY BASE FILE 2018-01-02 MF Import
>
Address Records
>
EVERGREEN WAY
>
11802
>
BASE FILE
>
11802 EVERGREEN WAY BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2020 11:33:08 AM
Creation date
2/10/2017 12:00:35 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
11802
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� I <br /> most cases, botl� sides of the a.:cess road shall be marked. Where loug drives a��e to be marked, the <br /> repeti�ions shall alternate sides of the dri��e. <br /> c. Marking shall also indud� U�c addition of inetal signs st.tting '"d0 PARKING - FiRC LANE- <br /> TOW AWAY ZONE' to be installed at intervals or loc.iions des�gn^red by ti�e !im. code official. <br /> The si�ns shall be approximately 12 inches in width and 1R inci;es in t�e �t��� ���c': '.�,� �; c;:,i l�tters cu a <br /> white background. Metal signs shall be installed on eithe. 2-i�1Clt me:a! :•:'•'_•. �'��' �;ri"a[e property or <br /> treated 4-inch by 4-incl� wood posts for public propert}� and shal( be loca[ed s� that the bottnm of the <br /> sign is a minimum of 7 feet above the curb. Where lire lanes are adjacent to buildiugs or structures <br /> and wl�en approved or directed by the tire code official, the signs may be placed on the face of the <br /> building or structure. <br /> E Where directed by the fire code officiat, specific areas shall be designated and those areas are to be <br /> marked with diagonal striping across the widQ� of the fire lane. Diagonal marking shall be used in <br /> conjunction �vith painted curbs and/or edge striping and shall run at an angle of 30 to 60 degrees <br /> from one side to the other. These diagonal lines shall be in red traffic paint, paralfel with each other, <br /> at least 6 iriches in width and 24 inches apart. Lettering shall appear as above. <br /> 5. Securitv �ence - Any security fence erected arom�d the construction site shall be located so as to not <br /> obstruct any cxisting hydrant, tirc protection equipment, or Fire Department access. [f Fire <br /> Department access is obstructed, gates or other openings shafl be provided for access. <br /> G. Premise [dentification - Premiscs shall he cleariy identified by the correct address at the street entry. <br /> f3uiWings siudl bc clearly idcntified so as to be visible and legible from the access road. Individual <br /> aparUncnts and suites, wherc applicablc, shall be dearly ai�d legibly identiticd 1'rom the access road. <br /> ?. Fire Hvdrants - Locations as plaimed are acceptable. <br /> 8. Qased upon 11,587 square feet of Type V-B, sprinklered consu•uction, the fire tlow reyuirement is <br /> I,S00 gpm. <br /> 9. Pire Sunnression (Snrinkler) System - An approved automatic suppression system sl�all be provided as <br /> required by City Ordinauce No. 1902-92, Chapter 16.76, of the Everett Municipal Code. The system <br /> �uust include a meclianical water gong bell. Plans for any such system shall be submitted to the <br /> I3uilding Dcpartment tbr exaiuination and approvaL Such plans shall include plans for the <br /> underground mains that will supply Utc sprinkler system. The type of sprinkler to be installed will <br /> be determined by U�c I3uilding OfticiaL It may be an NFPA 13, NFPA 13R, or NFPA 13D system <br /> depending upon several factors. Sprinkler installatiou shall not begin w�thout an approved and <br /> stamped set of plans from the [3uilding Department. The Fire Department will also review the <br /> plans and shall Gcld inspect the installation based only on approved plans that must be on site. <br /> Changcs to plans must be approved by bodi the Building and Fire Departments. Aboveground sprinklcr <br /> piping shall Ue hydrosta[ically tested as established in NPPA Standard 13. Underground piping shall <br /> be irydrostatically tested and (lushed as establislied in NFPA Standard 24 for private fire mains. <br /> (I3clow-eroimd nipine must be iustalled bv �Vashin�ion State Patrol Licensed Underaraund <br /> Sprinklcr line certified "U" installers. For further information, contact the State Fire Nfarshal's <br /> Office at (360) 570-3134 or contacf the E��erett Fire llepartment at (425) 25'1-8123.) All such tests <br /> shall Uc witnessed by a Pire Deparnnent inspccror. Call (425) 257-8124 to make an appointment tbr <br /> �tp ]. <br /> ��� <br />
The URL can be used to link to this page
Your browser does not support the video tag.