My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8625 EVERGREEN WAY SOCIAL SECURITY 2016-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
8625
>
SOCIAL SECURITY
>
8625 EVERGREEN WAY SOCIAL SECURITY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2017 1:17:55 PM
Creation date
2/10/2017 1:17:38 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8625
Tenant Name
SOCIAL SECURITY
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> IJ'v��... I. � �� <br /> ��' Kj1! <br /> .r. , iSw'� ����,� �O/i/V <br /> i .n��� <br /> Janusry 25, 1999 <br /> Van E. Swearingen <br /> Material Resource Administration <br /> 701 Sth Aveuue, MS 51, .;uite 2900 <br /> Seattle, WA 98104 <br /> Dear Mr. Swearingen: <br /> Regarding the Area Separation Wall (F.SW) in the South Evergreen Plaza Building, we have <br /> determined that this wall mLst be maintained at its present !ocation in the building. This wall <br /> is required per Uniform Building Code (1997) requirements for a Type V building with two <br /> floors gieater than a total of 16,000 square feet. Here we have about 26,000 square feet for <br /> the total building. Therefore, Section 504.6.2 requires a two-hour fire-resistive area <br /> sep�ration wall be maintained from Uie foundation to th� roof deck that divides the building <br /> ituo two sections with at least one section equal to or less than 16,000 square feet. Previous <br /> plans indicate the location of diis existing wall to be running east-west from the south ]obby , <br /> wall directly east or. a straight line. Any penetrations made into this ASW must have 90- <br /> minute fire-resistive frames and doors on closers or magnetic hold open devi-;s. This wall <br /> will extend to the roof deck and fan out five feet on either side for fire protection. <br /> At the meeting with Connell Design Group, we tried te facilitate a change in this wall <br /> location. However, the siting of the building on the property, the building type (V), and the <br /> existing location of the ASW on the first level, precluded any possible compromise of the <br /> location of this ASW. In this case, there is no way to mitigate the location of the ASW. <br /> As soon as your modified plans are ready for resubmittal, your application will be given <br /> priority and the plan review will commence. <br /> Sincerely, <br /> � <br /> � <br /> Tony Lee <br /> Associate Engineer <br /> TL:juAyi(onl�r7� <br /> CITY 0�EVERETT• 3200 Ce�ar Sfreet • Everalt,WA 98201 • (425) 257-8800 • Fax(425)257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.