ICClAN51 A117,1-2003 <br />604.3 Clearance. <br />✓ 604.3.1 SIze.Aclearancearoundawatercloset <br />60 inches (1525 mm) minimum, measured per- <br />pendicular irom the sidewall, and 5G inches <br />(1420 mm) minimum, measured perpendicular <br />irom the rear wall, shall be provided. <br />� 604.3.2 Overlap. The required clearance <br />around the water closet shall be permitted to <br />overlap ihe water closet, associated grab bars, <br />paper dispensers, sanitary napkin receptacles, <br />coat hooks, shelves, accessible routes, ciear <br />iloor space at other fixtures and the turning <br />space. No otheriixtures orobstructions shall be <br />within the required water closet ciearance. <br />Other fixtures not allo���ed <br />,.,,��.;.. ��.:.. ,,.,... <br />IOLJ <br />Fig. 604.3 <br />Size of Clearanco far Vdater Closet <br />� 604.4 Height. The height of water closet seats shall <br />be 17 inches (430 mm) minimum and 19 inches <br />(485 mm) maximur� �bove the iloor, measured ta <br />the top of the seatlSeats slielfnof6e sp�ung to re-�` <br />tum to a lifted position. <br />EXCEPTION: A water closet in a toilet room for <br />a single occupant, accessed only through a pri- <br />vate office and not for common use or public use, <br />shall not be required to comply with Section <br />604.4. <br />604.5 Grab Bars. Grab bars for water closets shall <br />comply with Section 609 and shall be provided in ac- <br />cordance with Sections 6tl4.5.1 and 604.5.2. Grab <br />bars shall be provided on the rear wall and on the <br />side wall closest to the water closet. <br />EXCEPTIONS: <br />1. Grab bars are not required to be instailed in <br />a toilet room for a single occupant, accessed <br />only through a private oftice and not for com- <br />Chapter 6. Plurnbing Elements nnd Facilities <br />17— 19 <br />30 — 485 <br />Flg, G04.4 <br />Water Closet Helght <br />mon use or public use, provided reinforce- <br />ment has been installed in walls and located <br />so as to permit the instaliation oi grab �ars <br />complying with Section 604.5. <br />2. In detention or correction facilities, grab bars <br />are not required to be installed in housing or <br />holding cells or rooms that are specially de- <br />signed without protrusions for purposes of <br />suicide prevention. <br />3. In Type A units, grab bars are not required to <br />be installed where reinforcement complying <br />with Section 1003.11.4 is installed for the fu- <br />ture installation oi grab bars. <br />4. In Type B units located in institutional facili- <br />ties and assisted living facilities, two swing- <br />up grab bars shall be permitted to be <br />installed in lieu of the rear wall and side wall <br />grab bars. Swing-up grab bars sh�il comply <br />with Sections 604.5.3'and 609. <br />5. In a Type B unit, where fixtures are located on <br />both sides of the water closet, a swing-up <br />grab bar complying with Sections 604.5.3 <br />and 609 shall be permitted. The swing-up <br />grab bar shall be installed on the side of the <br />water closet with the 18 inch (455 mm) clear- <br />ance required by Section 1004.11.3.1.2, <br />604.5.1 Fixed Side Wall Grab Bars. Fixed <br />sidewall grab bars shall be 42 inches (1065 <br />�,. mm) minimum in length, loca ed 12 inches (305 <br />mm) maiamum irom the rear wall and extending <br />54 inches (1370 mm) mir:imum lrom the rear <br />`�wall. In eddition, a vertical grab bar 18 inches <br />(455 mm) minimum in length shall be mounted <br />i„with the bottom of ihe bar located between 39 <br />" inches (990 mm) and 41 inches (1040 mm) <br />above the iloor, and with the center line of the <br />bar located between 39 inches (990 mm) and <br />41 inches (1040 mm) from ihe rear wall. <br />EXCEPTIONS: <br />1. In Type A and Type B units, the vertical <br />grab bar component is not required. <br />� I 47 <br />��' 2, ° i �l <br />