Chflpter 6. Plumbinp Elements nnd Fncilitios <br />2. In a Type B unit, when a side wall is not <br />available tor a 42-inch (1065 mm) grab <br />bar, the sidewall grab bar shall be per- <br />mitled to be 18 inches (455 mm) mini- <br />mum in length, located 12 inches (305 <br />mm) maximum irom the rear wall and <br />extending 30 inches (760 mm) mini- <br />mum from the rear wall. <br />39-41 <br />990 — 1040 � <br />54 min �E ,'( <br />12 mex 1370 �° p <br />305 , � ' <br />, 42 min , <br />Sectlon 609.4 \ <br />� v <br />m � <br />� cn a <br />I I <br />m d <br />Flg. 604,5.7 <br />Side Wail Grab Bar for Waler Closet <br />0 <br />v <br />a � <br />i i <br />°� o <br />� �, <br />rn <br />604.5.2 Rear Wall Grab Bars. The rear wall <br />/ grab bar shall be 36 inches (915 mm) minimum <br />in length, and extend from the centerline oi the <br />water closet 12 fnches (305 mm) minimum on <br />the side closest to the wall, and 24 inches (610 <br />mm) minimum on the transter side. <br />EXCEPTIONS: <br />7. The rear grab bar shall be permitted to <br />be 24 inches (610 mm) minimum in <br />length, centered on the water closet, <br />where wall space does not permit a grab <br />bar 36 inches (915 mm) minimum in <br />length due to the location of e recessed <br />fixture adjacent to ihe water closet. <br />2. In a Type A or Type B unit, the rear grab <br />bar shall be permitted to be 24 inches <br />(610 mm) minimum in length, centered <br />on the water closet, where wall space <br />does not permit a grab bar 36 inches <br />(915 mm) minimum in length. <br />3. Where an adminisfrative Authority re- <br />quires ilush controis for ilush valves to <br />be located in a position that conflicts <br />with the Iocation of the rear grab bar, <br />that grab bar shall be permitted to be <br />split or shifted to the open side of the toi- <br />let area. <br />na <br />ICC/AN51 A717.1 �2003 <br />36 min <br />915 12 min <br />24 min 305 <br />sto <br />a <br />� m <br />� � o <br />m m m <br />I I c <br />0 <br />m � U <br />m <br />� <br />� <br />Fig. 604.5.2 <br />Rear Wall Grab Bar for Water Closet <br />604.5.3 Swing•up Grab Bars. Where swing•up <br />grab bars are installed, a clearance of 18 inches <br />(455 mm) minimum fr�m ihe centerline of the <br />water closet to any side wail or obstruction shell <br />be provided, A swing-up grab bar shall be <br />installed with the centerline oithe grab ber 153/4 <br />inches (400 mm) from the centerline oi the wa- <br />ter closet. Swing-up grab bers shall be 28 inch- <br />es (710 mm) minimum in length, measured irom <br />the wall to the end of ihe horizontal portion of the <br />grab bac <br />Fig. 604.5.3 <br />Swing-up Grab Barfor Water Closet <br />604.6 Flush Controls. Flush controls shall be hand <br />operated or eutomatic. Hand operated flush con- <br />trols shall comply with Sect(on 309. Flush controls <br />shall be located on the open side of the w�ater closet. <br />