Laserfiche WebLink
TO: <br />FROM: <br />DATE: <br />SUBJECT: <br />Gordon Witcher <br />Jane Zimmerman <br />May 15, 1991 <br />Auto Sales Lot at 9815 Evergreen Way <br />Prior to approval of the proposed olans for the <br />property the following requirements must be met <br />provided: <br />1) a vegetated swale per <br />stormwater runo"f from paved <br />from the site. <br />2) an area specially designated for car washing that is <br />hydrologically isolated from the rest of the site, <br />preferably under cover, that drains to a baffle type <br />uil/water separator designed per City staTMdards^pr4o' to <br />discharging to the sanitary sewer. A ;r-r--�"'}� <br />ram i4 Y - <br />City standards to <br />surfac��s prior to <br />subject <br />or items <br />treat all <br />discharge <br />Iwdtisi.'[i��-➢ �_�P=}'"':'t p,-•,g . <br />The oil/water separator mainten- <br />ance notes from section�4.11.1 of the City's current Desiqn <br />and Construction Standards and Specifications must be <br />included if an oil/water separator is necessary. <br />g� a note on the storm drainage plans indicatinq that <br />washing of cars on the site is not allowed exWi�h Watereonl� <br />specially designated area. Pressure washing <br />is acceptable outside the designated wash area. <br />4) the requirements of sec�ion 4.7•1 of the City's <br />current Design and Constructio;i Standards and Specifications <br />must be met if ar�y auto repair or maintenance willlansu� on <br />the site. �tstatinq thattautosrepairdand maintenance <br />specifically <br />activities are not allowable on the site. <br />5) type and elevations (rim and invert) of exisiinq and <br />proposed catch basins. <br />6) the minimum required storm drai,nage plan notes found <br />in section 4.4.2.1 of the Desiqn and Construction Standards <br />and Specifications. <br />