Laserfiche WebLink
COMPLIANCE <br />REQUIRED Gr <br />INSPECTION <br />APPROVED <br />I-M-11u <br />E <br />W <br />�0110 <br />E310 <br />0 O <br />Cam: p <br />AW <br />O C <br />1 0 0 <br />O O <br />1look � <br />_i J 10 <br />describe your building or equipment.170 NOT <br />IMPORTANT: Disregard topics that don't <br />place checks In the two left columns. <br />Alrtlow from habitable rooms to whole -house fan ensured by undercut doors or grills (VIAO, S. 302.6.4) <br />Looseflll Insulation OK if (S.502.1.4.5): <br />❑maximum ceiling slope < 3 in 12 <br />❑z 30" of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br />6 trill black polyethylene ground cover, lapped 12" at joints and to foundation wall <br />Clearances shall meet listed minimums between Insulation and (S.502.1.4.3): <br />❑ chimney ❑ Non -IC rated recessed lights:112" to combustables, 3" to insulation. <br />Attic hatch shall be Insulated to required ceiling R-value and is weatherstripped (S.502.1.4.4) <br />lAttic access shall have wood dam or equivalent to retain loose fill insulation in attic (S. 502.1.4.4) <br />)AII exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />jservice hot & cold water piping shall be insulated to R•3 (S. 503.11) <br />JSarvlce recirculation hot water piping shall be insulated to Table 5-12 levels <br />herrnostat provided for each HVAC system with range of 55-75' R(heating) (S.503.8.1.1 )• <br />Readily accessible, automatic or Manual means provided to restrict or shut-off Heating input's each <br />zone or floor during periods not requiring heat (S. 503.8.3.1). S. 503.2.2(3)). <br />)controls tar backup heat prohibit similtaneous operation of the primary system <br />Mechanical ventilation systems shall have proper timers, and/or switches (S. 302.3). <br />)Mechanical ventilation ducts shall have insulation a R-4 in unconditioned spaces (VIAO, S.302.5) <br />Mechanical supply ducts in conditioned spaces shall have,, R-4 Insulation (VIAO, S.302.5) <br />upply ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />supply and r2wrn air ducts shall have sealed duct joints in unconditioned spaces (S. 503.10.2). <br />HVAC plenums, supply, and return air ducts shall have R-8 insulation (Table 5-11. All options) <br />Electric water heater(s) shall have (S. 504.2.1, 504.3, 504.4)O 1987 NAECA table on tank <br />❑ separate power shut-off Ternperature setting 120 F. <br />❑ noncompressible R10 pad (unheated spaces only) ❑ s <br />DIShowers and lavatories shall limit flow to s 3.0 gallons/minute (S. 504.8.1). <br />r Swimming POCKS) (S. 504.5) shall have: <br />in readily accessible ON/OFF switch (pump, heater) ❑ Pool cover ❑ Piping insulated to S. 503.11 <br />DFirepiace(s) (VIAO, S.402.3) shall have: <br />[3 6 square inch combustion air supplyduct wl operable damper, directly connected to the fire box <br />[:3 Tight fitting glass or metal doors; or flue draft induction fan. ❑ Tight fitting flue damper. <br />]Solid fuel burning appliance(s) (VIAO, S. 402.2) shall have: <br />❑ Tight fitting glass or metal doors <br />❑ Outside combustion air source directly connected to the fire box <br />❑ Exception: Non -direct, 4" diameter, dampered, combustion air source: allowed only for (1) new stove <br />installations in existing homes where obstructions preclude direct combustion air, or (2) Central <br />heating systems located in unheated spaces. <br />Three month, etched track, radon monhor, printed instructions, and an information sheet shall be <br />supplied by the builder to each single family dwelling and to each ground floor unit of mufti -family dwellings <br />(VIAO, S. 502.2.1). <br />WSEC Final phase <br />lnsperfed byLL�:3S( <br />Page 6 of 6 <br />