My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3611 FEDERAL AVE 2018-01-02 MF Import
>
Address Records
>
FEDERAL AVE
>
3611
>
3611 FEDERAL AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2022 2:23:54 PM
Creation date
2/10/2017 4:07:52 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3611
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P � <br />!HffJ � <br />May 27, 1999 <br />Kathleen Jones <br />3510 Oakes Avenue <br />Everett WA 98201 <br />Subject Owner: <br />Job Address: <br />Plan Check No. <br />Dear Ms. Jones: <br />Jones <br />3611 Federal Avenue <br />60171 <br />Pp <br />In response to your application for a construction permit, your plans have been examined <br />and you are advised that the issuance of a permit is being withheld for the reasons listed <br />below. These comments address building issues only, additional revisions or additions <br />may be required by other departments (such as Utilities. Planning or Fire). All <br />references refer to the 1997 Uniform Building Code, as amended by the State of <br />Washington and/or Washington State Energy Code 1997 Edition, unless stated <br />otherwise. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Division with two complete new sets of drawings reflecting the <br />Gcorrections requested. <br />1141. Provide cross section(s) through office/master bedroom, entry/stairs and new <br />garage. <br />2. Provide min. R-19 insulation at below grace walls that separate heated space from <br />unheated space. <br />' 3. Winding stairs shall have no width of run less than 6" at any point. <br />4. The plans do not meet the prescriptive requirements for lateral bracing. Provide <br />lateral analysis for wind and seismic loading prepared by a licensed Wa. St. <br />Structural Engineer. <br />/5. Concrete walls with more than Y-6" of unbalanced backfill are required to be <br />designed by a licensed Wa. St. Structural Engineer (wall between the garage and <br />entry). <br />CITY OF EVERETT• 3200 Cedar Street 9 Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.