My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3611 FEDERAL AVE 2018-01-02 MF Import
>
Address Records
>
FEDERAL AVE
>
3611
>
3611 FEDERAL AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2022 2:23:54 PM
Creation date
2/10/2017 4:07:52 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3611
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Provide detail of connection at slab-on-grade/foundation wall between garage and <br />entry. <br />7. Provide rigid insulation at perimeter of slab -on -grade when slab is within 24" of <br />the finished grade and when slab is adjacent to an unheated crawl space. <br />1/8. Provide concrete footings under bearing wall of stairs in new entry. <br />9. Provide minimum 36" landing at all entrance/exits. Landings may be not more <br />than 8" below the finished floor when the door does not swing over the landing. <br />When the door swings over the landing the landing shall be not more than 1" <br />below the finished floor. <br />10. Provide safety glass in required hazardous locations. <br />11. Revise rear elevation to show revised plans. <br />12. Show footings for stairs coming off of deck kitchen/dining room. <br />13. Change roof -framing plan to reflect changes to the "back entry" <br />14. Clarify floor framing at "back entry" of the floor above. <br />15. Provide smoke detectors in all sleeping rooms (defined as room w/closet) and in <br />the corridor or area giving access to each separate sleeping area. Detectors shall <br />be installed on each story and in basements. <br />16. Provide one -hour fire resistive construction on the walls and soffit of useable space <br />under stairs. <br />Provide a response letter showing where each item in this correction l,:tter is addressed <br />on the plan set. <br />Upon resubmital of the drawings, your application will be given priority and plan review <br />will commence. <br />All required submittals shall be of sufficient detail and contain sufficient information to <br />ensure that the proposed structure will be constructed in compliance with all adopted <br />codes. <br />Siucer ly. <br />_ � <br />Jeff Heilman <br />Development Technician <br />tteirf:60171 <br />
The URL can be used to link to this page
Your browser does not support the video tag.