My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4526 FEDERAL AVE 2018-01-02 MF Import
>
Address Records
>
FEDERAL AVE
>
4526
>
4526 FEDERAL AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2022 1:45:42 PM
Creation date
2/10/2017 4:41:41 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
4526
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
542
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 14, 1972 <br />Luther Child Center <br />Page Four <br />2. Separate the play area, recreation room, hall, storage, and toilet <br />room from the areas above by at least 1-hour construction including <br />all columns and structural components. <br />The door assembly for Doors 172 and #3 which includes the frame and <br />hardware, shall rate 1-hour for an occupancy separation. Swing doors <br />in direction of. egress. <br />Reference Section 1703, UBC, 1970. <br />Any glass lights shall be '�, inch wired plate glass and of a size <br />as permitted by the listing. <br />Comparable doors to stair on the first floor should be 1 3/4°approved <br />doors as noted above. <br />3. We suggest you provide a 3/0 door and reverse the swing of the door <br />now noted as 7#6 between multi -social. room and corridor #114. <br />4. Provide a 2k gallon pressurized water type fire extinguisher in the <br />first floor corridors and in lower level hall to service the basement <br />axea. <br />5. Provide exit and pathway lighting which must be on at all times when <br />the building is occupied. (Type of switching only as approved by the <br />State Electrical Inspector) <br />6. Provide a manually operated electrically supervised fire alarm system <br />and an automatic smoke detector system is corri.docs and heat acuuated <br />detectors in critical areas as required by Fire Alarm Requirements <br />WAC 212-14. <br />Shop drawings of the system shall be submitted by the fire alarm con- <br />tractor of equipment supplier for review and approval prior to installation. <br />We do note your reference to such system for all buildings on Sheet- A-4. <br />We are enclosing FA Requirements, 14AC 212-14. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.