Laserfiche WebLink
, . . � � <br /> — 22.Specify tempered safety glass in hazardous locations as defined in section <br /> R308 IRC. Show on plans and window schedule. <br /> SFe sheets A1.1, A1.2 and A9.0 <br /> 7_3.Window schedule calls out U-0.60 while a note on the drawing states "all <br /> vertical glazing to have a minimum U-factor of 0.32." Specify which option <br /> from table 6-1 WA State Energy Code (WSEC} is proposed, or provide a <br /> chapter 5 component performance calculation. (Note: 0.32 is the maximum U- <br /> factor for option II iiot the minimum). <br /> Disregard note on drawings stating, "all vertical glazing to have a minirn��m <br /> U-factor of 0.32." All new windows are to have a U-factar of 0.60, as stated <br /> in the window schedule (sheet A9.0). Refer to sheet G1.0 for Energy Code <br /> Compliance. <br /> � 24. Provide window header sizes, species and grade at locations where window <br /> size is increased or loads are increased, such as at windows in living room <br /> adjacent to the fireplace and window at eating nook. <br /> See framing plans (AF1.1, AF1.2, AF1.3}. <br /> _ 25.Show floor framing above Den/Kitche�� Trace all gravity loads to the <br /> foundation. <br /> See framing plan AF1.2. <br /> _ 26. Door from the dwelling into the garage cannot swing over steps. Provide <br /> landing in garage, or change door swing. <br /> NIA. There is no step between dwelling and garage. <br /> — 27.Specify size of all windows and doors. Show on plan view. <br /> See floor plans (A1.0, A1.1, A1.2). <br /> — 28.Provide exterior guard detail. Show how guard is attached to deck structure. <br /> See detail #2 on sheet A8.0. <br /> � <br /> — 29.Provide section and details for deck construction. Show how 5-1/4"x9" PSL is <br /> protected from exposure to the weather. <br /> See detail #2 on sheet A8.0. 5-114"x9" PSL switched to 6x12 P.T. DF #1. <br /> `�I�r <br /> �> <br />