Laserfiche WebLink
� ' � � <br /> � Botesch, Nash 8 Hall <br /> Architects, P.S. <br /> May 10, 2013 <br /> ATTN: Jeff Heilman <br /> City of Everett <br /> RE: Jorgensen Residence <br /> 4710 Gardner Ave <br /> Plan Check # C1303-007 <br /> Architectural Commen��: <br /> � 1. All plans shall be "wet-stamped" and countersigned. <br /> See attached plans. <br /> ✓ 2. Specify header size, species and grade at dining room doors supporting new <br /> deck and bathroom addition. <br /> See attached structural ►esponse letter. <br /> ✓ 3. 6 x 6 post called out at landing on main tloor pian sheet AF1.2 will not fit into <br /> 2 x 4 walls. <br /> Co�ner of 6 x 6 post will be furred out with sheetrock. <br /> ----- 4. The "5.25 x 9.25 PSL (64)" beam does not appear to include the weight of the <br /> point load (rom the second floor in the calculation. Please verify beam size <br /> �with point load. � <br /> See attached structural response letter. <br /> �� 5. Pantry addition does not show insulation in floor. Show how addition compiies <br /> with ihe requirements of the �Nashington State Energy Code. (WSF_C) <br /> Floor in pantry will be built up to provide R-30 insulation in floor as <br /> required by WSEC (G1.0). See #2 on sheetA5.0. <br /> ��3 <br />