My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4711 GLENHAVEN DR 2016-01-01 MF Import
>
Address Records
>
GLENHAVEN DR
>
4711
>
4711 GLENHAVEN DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2017 4:23:11 PM
Creation date
2/11/2017 4:22:53 PM
Metadata
Fields
Template:
Address Document
Street Name
GLENHAVEN DR
Street Number
4711
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r . <br /> recommend that the foundation wa11s along the southem perimeter of the building be eztended <br /> 4 feet above ouuide grades. This feature wiil mitigate structural damage from potendal future, <br /> shallow-seated landsiide debris flows from the slope above. <br /> It should be noted that the area bounded by lines extending downward at 1H:1V from any <br /> footing must not intersect another footing or sofUdisturbed natural or fill soils. In addition, a <br /> 1.SH:1 V line extending down from any footing must not daylight because sloughing or <br /> raveling may eventually undemune the footing. Thus, footings should not be pia=ed near the <br /> edge of steps or cuts in the bearing soils. <br /> Lateral loads can be resisred by friction between the foundation and the supporting nawral or <br /> compacted fill subgrade, or by passive earth pressure acting on the buried portions of the <br /> foundations. Tl�e foundations m�st be poured "nea[" against the existing soil, or backfilled with <br /> - a compacted fill meeting the requireme.n[s of structural fill. We recommend the following design <br /> _ parameters: <br /> ' • Equivalent passive fluid density = 300 (pounds per cubic foot) <br /> • Coefficient of friction = 0.35 <br /> The above values include a factor of safery of 1.5. <br /> Anticipated setdement of footings founded on the natural, medium dense, silry fine sand and <br /> site soils prepared as previously reconunended should be on [Ue order of 1 inch or less. <br /> Iiowever, disturbed soil not removed from footing areas prior to placing the footings could <br /> result in increased se�tlemen�s. Footing subgrades should be inspected by AESI prior to <br /> placing concrete to veriCy tl�at d�e design bearing capacity of the soils has been attained and <br /> d�at construction confornu with the recommendations coniained in this report. Such <br /> - inspections may be required by the governing municipality. Perimeter footing drains should be <br /> provided as discussed under thc section on Drainage Considerations. <br /> 10.1 Retainine Walls <br /> To achieve the daylight basement elevations of the residence and to retain tbe upper slope solls <br /> witlrin the parking area as proposed, we anticipate that foundation retaining walls ranging from <br /> about 6 to 12 feet in height will be required. Due te the presence of loose fill soils wtvch exrend <br /> to depttu of approximately 12 feet below the base of the proposed parking area, we recommend <br /> diat the retaining walls consuvcted for this area be supported using drilled picr foundations. The <br /> piers would need to extend through the fill and be embedded within the underlying de��se [ill <br /> soiis. I'lease refer to the desien recommendations contained in the following Drilled Pier section <br /> of ttiis rcport. <br /> The proposed retaining walls should be designed ro resist tl�e lateral earth pressures imposed by <br /> the mtained soils. \Valis diat are designed to yield 0.001H, where H equals the heieht of the <br /> wall, may be designcd to resist the lateral earth pressure imposed by an equivalent fluid with a <br /> I1 <br />