My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4711 GLENHAVEN DR 2016-01-01 MF Import
>
Address Records
>
GLENHAVEN DR
>
4711
>
4711 GLENHAVEN DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2017 4:23:11 PM
Creation date
2/11/2017 4:22:53 PM
Metadata
Fields
Template:
Address Document
Street Name
GLENHAVEN DR
Street Number
4711
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
unit weight of 35 pounds per cvbic foot (pcfl. If the walls are to be restrained at the top from <br /> free movement, the equivalent fluid weight should be �• .ased to 55 pcf. <br /> These values are based on a horizontal backfillslope, and assume that no other surcharges due to <br /> steeper backfill slopes, hydrostatic pressures, savctural loads, trfric loads, or other surcharges <br /> loads will act on die wall. If such surchazges apply, they should be ��dded to the above design <br /> lateral pressure. Since craffic loads will lx exerted on the north retainiug walls located within the <br /> . upper parkin� area, we recommend that a vaffic load equivalent to 2 feet of additional bacicfill <br /> height be added�to the pressures recommended above. <br /> Retaining walls should be backfilled with a free-draining washed rock containing less than 5 <br /> pement fines ba,,ed on the minus No. 4 sieve fraction. The free-draining material should extend <br /> at least 18 inches behind the wall. The remainder of the badcfill may consist of compacted <br /> � natural soil. A perforated drainpipe should be placed at the base of the wall. The drainpipe <br /> . should be perforated with holes less than one-quarter inch in diameter, and surrounded by t}uee- <br /> eighths inch pea gravel. <br /> Compaction behind retaining walls should be completed with hand held equipment. Heavy <br /> equipment should not be used so that hi�li lateral wall stress does not develop and potentially <br /> damage the walls. <br /> 10 2 Drilled Piers for RetaininQ Wall Sunnort <br /> The fill soils located at the top of the soudi slope are not suitable for support of tbe proposed <br /> parking area retaining walls utilizing conventional foundations. Therefore, we recommend that <br /> the retauung wall foundations Ue extended throueh the loose fill and gain support within the <br /> underlying medium dense to dense till soils. These competeqt soils should be encountered at a <br /> � depth of about 15 to 20 feet below existing grades. <br /> Given the deep excavations required ro conswct conventional spread footings, we suggest that <br /> the retaining wall foundations ucilize drilled piers. Installadon of drilled piers consisu of placing <br /> concrete in pre-drilled, open holes. This rype of pier system requires that the sediments will not <br /> cave into the holes afrer auger �yithdrawal and during concrete placement. If the holes will not <br /> stay open, it may be necessary to case d�e l�oles. Based on observations during our field <br /> explorations, it is our opinion that die holes will generally stay open during and immediately <br /> following augering. We reconunend die use of a flexible drop clwte or concrete pump �vith its <br /> hose extended to the bottom of d�e l�ole to assure that seepage is adequately displaceu during <br /> concrete pumping. Tliis method would also tend to reduce the amount of sloughine caused by <br /> concrete liitting the side of the l�ole as it is placed. <br /> Por preliminary estimating purposes, a 16 inch diameter drilled pier penetratin� ro a depdi of 25 <br /> feet below existing erades (minimum 4 feet into bearing lodgemcnt ull soil) may be desiened <br /> using an allowaUle venical loading of 10 tons, and an allowable uplifr load'uig of 3.5 l:ips. Each <br /> pier ma�� be desiened to resist a lateral loading of 0.5 ton at a deflection of 0.35 inch. Allowable <br /> 1' <br />
The URL can be used to link to this page
Your browser does not support the video tag.