, <br /> 1 <br /> • � � <br /> Jordan Construction JN 00284 <br /> July 25, 2000 Page 4 <br /> overexcavation and the footing width. For example, an ove�excavation extending 2 feet below the <br /> bottom of a 2-foot-wide footing must be at least 4 feet wide at the base of the excevation. If lean <br /> concrete is used, the overexcavation need only extend 6 inches beyond the edges of the footing. <br /> An allowable bearing pressure of 2,000 pounds per square foot (ps� is appropriatE for footings <br /> supported on competent, native soil, imported structural fill, or lean mix concrete. A one-third <br /> increase in this design bearing pressure may be used when considering short-tertn wind or seismic <br /> loads. For the above design criteria, it is anticipated that the total post-construction settlement of <br /> footings founded on competent, native soil, or on structural fill up to 5 feet in thickness, will be <br /> about one-half inch, with differential settlements on the order of one inch in a distance of 50 feet <br /> along a continuous footing with a uniform load. <br /> Lateral loads due to wind or seismi: forces may be resisted by friction between the founda!ion and <br /> the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the <br /> foundation. For the latter condition, the foundation must be either poured directly against relatively <br /> level, undisturbed soil or be surrounded by level structural fill. We recommend using lhe following <br /> design values for the foundation's resistance to lateral loading: <br /> Coefficient of friction 0.40 <br /> Passive Earth Pressure 350 pcf <br /> Where:(i)pef la pounda par cuble loot,and(ii)paaaiva a�rth <br /> pressure is computed ustng lhe equivalent fluld denslty. <br /> If the ground in front of a foundation is loose or sloping, the passive =arth pressure given above will <br /> not be appropriate. We recommend a safety factor of at least 1.5 for the foundation's resistance to <br /> lateral loading, when using the above design values. <br /> SEISMIC CONSIDERATIONS <br /> The site is located within Seismic Zone 3, as illustrated on Figure No. 16-2 of the 1997 Uniform <br /> Building Code (UBC). In accordance with Table 16-J of the 1997 UBC, the site soil profile is best <br /> represented by Soil Profile Type S� (Very Dense Soil). The site soils are not subject to seismic <br /> liquefaction because of their dense nature and the absence of near-surface groundwater. <br /> SLABS-ON-GRADE <br /> The building floors may be constructed as slabs-on-grade atop medium-dense, weathered, gravelly <br /> sand overlying the dense till. The concrete slab could be placed on the existing fill �f steps are <br /> taken to till up th� existing fill soils, re-roll, and compact them according to the <br /> recommendations di..cussed later in the GENERAL EARTHWORK AND STRUCTURAL FILL <br /> section of this report. The subgrade soil must be in a firm, non-yie!ding condition at the time of slab <br /> construction or underslab fill placement. Any soft areas encountered should be excavated and <br /> replaced with select, imported structural fill. <br /> GEOTECH CONSULTANTS,INC. "�� <br />