My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5300 GLENWOOD AVE 2018-01-02 MF Import
>
Address Records
>
GLENWOOD AVE
>
5300
>
5300 GLENWOOD AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2022 10:28:18 AM
Creation date
2/11/2017 6:54:05 PM
Metadata
Fields
Template:
Address Document
Street Name
GLENWOOD AVE
Street Number
5300
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
875
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. The roof drainage system shuuld be a tight-line system and the footing drains should be <br /> independent Crom them. UPC Appendi� D-1 & Soils Report (see structural). <br /> Occupaucy <br /> l. The Projec[ Data section of the Cover Sheet should show that this is an R-1 <br /> Occupancy. Table 3-A. <br /> 2. An appraved automatic fire suppression system is required per City of Evcrett <br /> Ordniance 16.76 for the Type A building. <br /> 3. An approvcd automatic fire detection system is requimd per City of Everett Ordniance <br /> iG.76 forthe Type A building. <br /> 4. Thc occupanr,y separation between the garage and dwelling unit is required to be a full <br /> one-hour separation as E�ception #3 to Section 302.�1 docs no[ apply to R-1 <br /> Occupancies. Qased on this, th�: following comments apply: <br /> a. The occupancy scparation wall should bc a listed one-hour fire-resistive assembly. <br /> Section 302.4. <br /> b. The door behveen the garage and dwelling should be sho�vn as a minimum 60- <br /> minute rated, self-closiug assembly. Section 302.3. <br /> c. Ducts pcnetrating the occupancy sepnration requirc combination smoke/fire <br /> dampers. Sections 713.10 �C 713.11. <br /> d. Two laycrs of �/8" rype X GWQ should be sho��n at the bottom chord of the <br /> trusses to provide the fire separation. Section 302.4 and Item 21, Table 7-C. <br /> e. A one-hour rated tloor/ceiling assembly as tested in NER-200 (tire-resistive <br /> assemblies for TJI's) should be sho�vn between the garage and Bedroom #3. <br /> f. The �valls/structure supporting the horizontal occupancy separation should be <br /> shown as one-hour construction. Section 302?. <br /> 5. The toilet in the utility room should have a clear 24"x 30" space in front. Section <br /> 2904. <br /> 6. "fhe smoke detectors should be specified to have battery backup. Section 3109.1.3. <br /> Construction <br /> L A moisture barrier should be shown under the �vood siding. Sectiott 1�102.1. <br /> 3. Und�riloor beams should be shown at least l3" above grade. Section 23 U.3. <br /> 1�� � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.