Laserfiche WebLink
3. Attic vent sizes, locations, and screening details should be shown on the plans. <br /> Ventilation calculations should be provided. Section 15053. <br /> 4. A 22" x 30" attic access opening should be provided in a readily accessible location <br /> for each separate attic area. Access should be provided in a location �vith a minimum <br /> headroom clearance of 30". Section I50�.1. <br /> Energy <br /> L Prescriptive path [V requires a minimum of R-19 insulation (with 2x6 studs) for walls <br /> abova grade. The typical wall section on Sheet 6/21 should be revised or a component <br /> analy..is should bc provided. <br /> 2. The location of the whole house fan should be shown on the plans (80 cf'm minimum <br /> for 3 bedrooms). Section 304, Washington State Ventilation Code. <br /> UNIT-A STRUCTURAL <br /> L The ground in the underfloor area as shown in the Typical Wall Section, Sheet 6 <br /> should not be excavated below the top of die footings. Footnote 2 to Table 18-I-D. <br /> 2. All spread footings should be a minimum of 2�3" s 24". Per Geotechnical Report, <br /> Nelson-Couvrette& Assoc., May 12, I994 (further references noted as `Soils Report'). <br /> 3. Tlie garage footing �ho�vn on Sheet 6 should be shown as a minimum of 16 inches <br /> wide per the Soils Report. <br /> -{. .A design criteria for re-drilling should be provided on the plans such that the contractor <br /> may I:now (and our inspectors to verity) how to space re-drilled holes around an <br /> abandoned pile if necessary. Soils Repon. <br /> �. A positivc connection should be provided betwcen the post and spread footing as <br /> shown on Shect 6. <br /> 6. 1'he bird blocks should either be sct vertically �tiidi rops beveled for good nailing <br /> surfacc, or be fastened �vith metal clips designed to transfer lateral loads from blocks to <br /> top platcs. <br /> UNIT-13 NOY STRUCTURAL <br /> General <br /> I. 'The distance beh�een buildings should be shown. 1'he minimum distance of 4 feet <br /> slwuld be sho�vn separating the decks of die adjacent duplexes. Section �03.2.1. <br /> (�/'., \ <br /> �-/ <br />