Laserfiche WebLink
3. Thc exterior walls supporting the occupancy separation between the garage and <br /> dwelling unit above should be shown as having a layer of 5/8" type X GWII (interior <br /> side of�vall). Section 302.3 <br /> 4. The details for the water-proof exterior deck over the garage should be provided. The <br /> minimum slope of 2°/a should be shown. Section 1506.1 <br /> 5. The sliding glass door should be shown to have a minimum 33" deep landing no lo�ver <br /> than 8" below tlie level of ihe interior floor. Section 1004.9 <br /> Accessible Unit <br /> Gencral <br /> L In addition to the general construction, energy and structural comments listcd for the <br /> above buildings, the following comments are specifically for the I-[C Unit. <br /> 2. Tltc walls surrounding the stairs should be shown as minimum I-hour assemblies as <br /> they arc dwelling unit separation walls. Section 310.2.2. <br /> 3. The glazing adjacent to the exterior door at the dining room in thc lower unit should be <br /> safety glazing. Section 2406.4. <br /> �1. Smoke detectors should be shown outside both of the bedrooms on the upper unit. <br /> Section 310.9.1.4. <br /> 5. A smoke detector should be shown at the bottom of the stairs to thc upper unit. Section <br /> 3109.1.�4. <br /> G. A smoke detector should be shown outside oC bedroom #1 on the first tlooc Section <br /> 310.9.1.4. <br /> 7. Tlte combustion air intake for the furnace adjacent to the stairs should be sho�vn. UMC <br /> Sections 703.�1 &: 706, U�1C, <br /> Acccssibilitv <br /> l. The sho�ver in the accessible unit should be either a rol(-in or transfer type. Sce <br /> attached details - note the dear tloor space required for each sho�ver type. <br /> 2. The accessible shower should have a lever-operating handle and a hand-held sho�ver <br /> spray on a 60" long hose mounted at a maximum of 48" above the floor. Section <br /> If06.11.10.5. <br /> 3. The kitchen in the accessible unit should have a 30" x 24" counter wid� a maximum <br /> heigiu of 3�1". Tl�e space beneath the counter should be at least 29" hich, 30" wide, <br /> and 19"- '?i" deep. Sectiuns 1106.3.3 S. I10G.1?.?. <br /> r � <br /> �i, i <br />