My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5300 GLENWOOD AVE 2018-01-02 MF Import
>
Address Records
>
GLENWOOD AVE
>
5300
>
5300 GLENWOOD AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2022 10:28:18 AM
Creation date
2/11/2017 6:54:05 PM
Metadata
Fields
Template:
Address Document
Street Name
GLENWOOD AVE
Street Number
5300
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
875
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. The roof drainage system should be a tight-line system and the footing drains should be <br /> independent from them. UPC Appendix D-1 & Soils Report. <br /> �. The smoke detectors should be specified to have battery backup. Section 310.9.1.3. <br /> 4. A moisture barrier should be sho�m und:r the wood siding. Section 1402.1. <br /> 5. Safety glazing should be provided for the window at the landing at top of the stnirs. <br /> Section 2406.4. <br /> 6. Attic vent sizes, locations, and screening details should be sho�m on the plans. <br /> Ventilation calculations should be provided. Section 1�05.3. <br /> 7. A 22" x 30" auic access opening should be provided in a readily accessible location <br /> fur each separate attic area. Access should be provided in a location with a minimum <br /> headroom clearance of 30". Section 1505.1. <br /> Encrgy <br /> l. Insulation should be providcd ���ithin the cavity of thc tloodceiling assentbfy separating <br /> the garage from the d�velling unit unless the garage is to be heated. [f the garage will <br /> be heated, than the garage door should be insulated and a component analysis should be <br /> provided. Table 6-2. <br /> 2. Prescriptive path IV requires a minimum of R-19 insulation (with 2x6 studs) for walls <br /> above grade. The typical wall section on Sheet 6/31 should be revised or a component <br /> analysis shoidd be provided. <br /> UNIT-13 STRUCTURAL <br /> l. The lowest wall studs (cripple wall in basement) should be shown 1s 2xGs whcn over <br /> d' in l�cight as they suppor[ more than one Floor and roof. Section '_'326.1 l.� & Table <br /> 23-I-R-3. <br /> UNIT-C NON STRUCTUR.4L <br /> Gcncr:il <br /> l. The general and stnutural dctails on Sheets •1-6 for building A are also for E3uilding C. <br /> Those comments will not be restated bclow but should also be addressed for Building <br /> C where applicable. <br /> 3. The minitnunt distance bet���een units should be sho�vn as 6 feet. Table �-A. <br /> �.} ; A <br /> c � <br />