My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1821 FULTON ST B 2016-01-01 MF Import
>
Address Records
>
FULTON ST
>
1821
>
1821 FULTON ST B 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2017 9:26:19 PM
Creation date
2/11/2017 9:26:09 PM
Metadata
Fields
Template:
Address Document
Street Name
FULTON ST
Street Number
1821
Unit
B
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
} � <br /> PUlS�/C L�YO/�K5 "�� <br /> May 24, 1996 <br /> Associated Rental Service <br /> PO Box 1622 <br /> Snohomish, WA 98291 <br /> Subject: Owner: Associated Rental Service <br /> Job Address: 1821 Fu1Wn <br /> Plan Check No: 51657 <br /> Dear Ms. Denney: <br /> In msponse to your a�plication for a construcdon permit, your plans have been examined and you <br /> are adv�sed that the �ssuance of a permit is being withheld for the reasons listed below. These <br /> comment: address huilding issues only, additional revisions or additions may be required by other <br /> departments (such ac Utilities, Planning or Fire). All references refer to the 1994 Uniform <br /> Building Code, as ai�iended by the State of Washington and/or Washington State Energy Code <br /> 1995 EdiGon, unless scated otherwise. <br /> In order for the processin�of your application to continue, it will be necessary <br /> to provide the Building ivis�on w�th two complete new sets of drawings <br /> reflecting the corrections requested. <br /> 1: All habitable rooms azere�uired to be provided with natural light and vendlation. The <br /> required area for natural light is 1/lOth of the floor azea, ventilation is 1/20th of the floor <br /> azea. Both bedrooms do not have sufficient light or ventilation. <br /> 2. Provide size of all windows and doors on the plans. <br /> All dwellings shall have an exit doorway of a size to permit the installation of a door not <br /> less than 3 feet (914 mm) in width and not less than 6'-8" (2032 mm) in height. When <br /> installed, exit doors shall be capable of opening so that the clear width of the exit is not <br /> less than 32 inches (813 mm). <br /> C3: All dwelling units shall be provided with a whole house ventilation system - Whole house <br /> ventilation systems shall supply outdoor air to all habitable rooms through individual <br /> outdoor air inlets, forced-air heaUng system, ducting or equivalent means. <br /> 4. Provide exhaust fans in each kitchen, b:,throom, water closet, laundry room and other <br /> rooms where excess water vapor or cooking odor is produced. Minimum 50 CFM fan in <br /> bathroom and laundry; minimum 100 CF!N :.tn in kitchen. <br /> S Specify on the plans that the whole house fan shall have a manual control and an <br /> automadc control. The automadc control timer shall be set to operate the whole house <br /> fan for a minimum of eight hours a day. <br /> CITY OF EVERETT•3200 Cedar Street• Everett, WA 98201 • (206) 259-8800 • Fax (206) 259-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.