Laserfiche WebLink
� �� <br /> Plan Check No. 51657 <br /> May 24, 1996 <br /> Page 2 of 2 <br /> 6. Provide smoke deteccors in all sleeping rooms and in the corridor or area giving access to <br /> each separace sleeping azea. Detectors shall be 110 volt with battery back-up. Detectors <br /> shall be interconnected. <br /> 7. � Corridors (hallway) shall be not less than 36" net clear width, show dimensions on plans. <br /> � Sleeping rooms shall be provided wiW at least one operable window or door approved for <br /> emergency escape or rescue. Fscapo or re�cue winde���s shall have a mimmum net clear <br /> openable area of 5.7 square fcet (0.53 m ), The minimum net clear openable width <br /> dimension shall be 24 inches(6 0 mm).) When wind ws areepr vided�a�snabmeansgof <br /> escape or rescue, they shall have a finished sill height of not more than 44 inches (1118 <br /> mm) above die floor. <br /> Prepare a response letter showing where each item in this correc6on letter is addressed on the plan <br /> set. <br /> Upon resubmittal of the drawings, your application will be gi..;a prioriry and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain su�cient information to ensure that <br /> the proposed swcture will be constructed in compliance with all adopted codes, <br /> Sincerely, <br /> .��L- j <br /> eff Heilman <br /> Development Technician { <br /> 111;jW�c(py��k�) <br /> I � <br />� � <br /> � � <br />� �C� '.�' '�'�f�'• - � ' _ .. . ' ' .. _,' ,. � .. . . � . . . <br /> :�'�-�;>x..- <br />