My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2313 COLUMBIA AVE 2018-01-02 MF Import
>
Address Records
>
COLUMBIA AVE
>
2313
>
2313 COLUMBIA AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2022 1:53:48 PM
Creation date
2/11/2017 10:55:24 PM
Metadata
Fields
Template:
Address Document
Street Name
COLUMBIA AVE
Street Number
2313
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•21 ® Install a 3/4" non-adjustable temperature and pressure relief valve on hot water tank <br />and a 3/4" discharge line to outside or to an interior drain. Rating of valve shall <br />not be greater than working pressure rating of water tank. <br />•22 O L7 (a) Replace all deteriorated rotted or damaged wood foundation and framing members, <br />including posts, plates, beams and joists in underfloor area, with sound material. <br />No wood to remain within 6" of ground. <br />Q (b) Replace all skirting and other wood in contact with the ground with material <br />resistant to rot and infestation. Finish all exposed new or repaired work to match <br />exterior. No wood to remain within 6" of ground. <br />-23 L/ Install new gutters, elbows and downspouts on main building. Apply primer and two <br />coats of exterior 15aint to match existing finish. <br />-24 :7 Install plastic laminate or equal to kitchen counter top and back splash after first <br />replacing any damaged or rotted underlay. <br />-25 D Install 8"xl4" galvanized hardware cloth screened crawl space area vents <br />of-- mesh one near each corner) to adequately vent crawl space area. <br />Note: Metal louvered nail on vents are not acceptable. <br />-26 Q Install an acceptable vapor barrier ground cover over entire crawl space area. <br />-27 u crawl space shall be graded and sloped to prevent ponding of seepage water. Install <br />drain tile in gravel bed connected to suitable outfall to provide positive drainage <br />away from dwelling. Cover entire crawl space with acceptable vapor barrier. <br />-28 G% Install 1/8" screened hooded roof or 1/8" screened louver type gabe vents to provide <br />positive cross ventilation of attic space. <br />-29 u Submit evidence that the leased 0 gas furnace burner 0 hot water tank has been <br />purchased from the utility company or has been replaced with new equipment and is now <br />part of the realty. (Leased equipment not acceptable). <br />:-30 0 Install a new forced air, wall, baseboard, or other heating system adequate to heat all <br />finished rooms to 700 Fahrenheit. Submit heat loss calculations and installation plan <br />for approval prior to installation. Space or room heaters are not acceptable in <br />dwellings of this type. If electric heat is installed, adequate insulation and wiring <br />and service panel are required to meet minimum housing standards of authority having <br />jurisdiction. <br />:-31 v Sand and refinish hardwood floors in the following rooms: <br />Painted fir floors may be repainted. NOTE: The installation of carpeting and cushion <br />meeting UM-44c standards in these areas is an acceptable alternate method of satisfying <br />this condition. Submit manufacturer's registry number and type of carpet to be used. <br />:-32 ta) The FHA value is based on a lot size of <br />D (b) Submit copy of correct legal description including lot dimensions. <br />-33 0 D (a) Since a portion of the land offered as security is deemed to be ineligible <br />excess land, the Deed of Trust or Mortgage shall cover only the following <br />parcel which is eligible: <br />(b) The portion of land to be deleted consists of: <br />-34 Q Submit evidence from the local authority having jurisdiction that the subject property <br />has been connected to the v public sanitary sewer system, 0 public water system. <br />-35 [] All special assessments for utilities and/or street improvements, either completed or <br />in the process of being completed, shall be paid in full and evidence of payment <br />submitted to this office when mortgage papers are presented for insurance. <br />36 Q Submit evidence that the subject property fronts on a street dedicated to and accepted <br />for continuous maintenance by the local authority having jurisdiction. <br />-37 Q Submit acceptable written evidence that a recorded perpetual joint use and maintenance <br />agreement exists for the private roadway serving the subject property. <br />EA Form 1019-q-113 (Rev. 8-1-75) <br />