Laserfiche WebLink
PUBL/C I�I/Ol�KS <br /> .�������s< <<�, �ooa <br /> rt�b�r� x;n��i� <br /> -47?�! Commcrcial A��cnuc <br /> L�u�ett, 1Vr\ 9S'03 <br /> Subject: Project: Kincaid <br /> Jub Address: 4715 Commcrcial r\venuc <br /> Plan Check No: CO^_OS-001 <br /> Dcar Mi. Kincaid: <br /> In response to your applic;uion for a consuuction perniit, your pl:ms have been examined .md �ou <br /> are advised that the issuance of a Pern�it is being withhcld (or thc reasons listed Uelow. These <br /> comments address buildine issues only. r\dditional revisions or additians may be required by other <br /> departments (such as Utilities, Planning or Fire). All references refcr to the 1)97 Uniform Buildine <br /> Code, as amcnded by the State of Washingron and/or Nashin�ton State Encrgy Code 2001 Edition, <br /> unless statcd othen��isc. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division ��•ith t���o co►nplete new sets of ura�vings reflecting <br /> tli� corrections requested. <br /> 1. Provide all information pertainin�� to the consh�uction oC decks. Size, location, footin;� <br /> size,joists, decking, guardrails etc. Show hoo� deck is attached to the structure. <br /> �. Where doors swing out. the max drop to die walkin� surface of the deck is 1" marimum. <br /> 3. Details R-9 and R-� on shcet Sec-1 show diat all roof rafters benr on top of the plate. The <br /> scction sho���s roof rafters bearing at a point belo�v the top plate. If the rafters are set on <br /> top of the top plate the over-all height of the building would exceed the maximum <br /> allowed height. Chanse cross section to represent the actual construction. <br /> �3. The cross section on Sec-1 sho�vs the height from the tinished tloor on the first floor to <br /> the finished Floor on the second iloor as 3'-0". The l l 7/S" floor joists �.vould reduce the <br /> ceiling height to less than the minimum 7'-6" required. � <br /> i. Show rooF ventilation calculations and size and location of roof��ents. <br /> 6. The plans call for a 5 �/a" x 16" parallam over the carport area. The plans also show 11 <br /> 7/3" iloor joists r,mtilevered over the beam. The bottom of the beam would be under the <br /> 7'-0" minimmn. <br /> 7. Show finished clevation of the tloor on each story and in the basement. <br /> I�I:UI i'I�Ct:]ISTAAIEIlSfn4iC'U!09-(101��)19C0?IMFA[IdL N'Ir. <br /> �;I�I�'�/ �`P ��/ERETT• :i�(i0 Cad=r Sheet • E��erett. `IJA �c�201 • �d25) 2�7-88C0 • Fex (d251 257-d8�u �Z <br />