My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4718 COMMERCIAL AVE 2016-01-01 MF Import
>
Address Records
>
COMMERCIAL AVE
>
4718
>
4718 COMMERCIAL AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2017 11:19:32 PM
Creation date
2/11/2017 11:19:20 PM
Metadata
Fields
Template:
Address Document
Street Name
COMMERCIAL AVE
Street Number
4718
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ltr. R.Kincaid (CO20S-001) <br /> August 20, 2002 <br /> Pa�c _' <br /> 3. Providc smokc dctectors per 3109 li[3C. Show on plans. <br /> 9. Show size and location of all required exhaust fans. <br /> l0. Show Washington Statc ventilation and indoor air quality code (VIAQ) requirements on <br /> pians, including whole house fan and fresh air inlets. <br /> I 1. Show U-value of all windows and doors on windon and door schedule. Specify open or <br /> fixed on window schedule. <br /> I'_'. Specify roofing material and moisture barrier for roof. <br /> l3. Provide cross section of stairs with lowcr ceiling hei�ht. It appears that the stairs do not <br /> maintain a minimum of G' — 3" for the lower portion of the stairs. <br /> 1-4. Specify 5/S" type 'a' GWB on walls and soffit of useablc space under the stairs. <br /> I5. Specify windo��� sizes in basemcnt. <br /> 16. Show how the house is heated. (If basement has capaciry to be heated, it is required to be <br /> insulated.) <br /> l7. Specify double top plates with splices lapped 43". <br /> t S. Specify size and type of material of rim joist. <br /> l9. Windows less than IS" nbove the floor arc reyuimd to be tempered �lass. Veiify windo�v <br /> sizcs in the Pmnily room and dining room. <br /> 30. Provide thernial break at perimeter of slab-om�radc when slab is less [han 2'-0" below <br /> the exterior grade. <br /> Please prepare a responsc lcttcr sho�cin�� wher� c:�ch item in this correction letter is addressed on die <br /> plan set. <br /> Upun resubmittal ol the dra��ings, your :�pplication �cill be �iven priority and plan review will <br /> recotnmence. � <br /> All required submittals shall be of sufficient detail and contain sufficient information to cnsure that <br /> the proposed structure will be constructed in comptiance �vith all adopted cudes. <br /> Sinccrcly, <br /> ���� <br /> ( <br /> Jeff Heilm.m <br /> Dc��dopmcnt Technician <br /> ❑I LI PI.,`:CL�6IAlILl1�I.M���I:J?inl i�';ISi UV1fi:HCLAL.AA'I.i � <br /> < �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.