My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6307 COMMERCIAL AVE 2016-01-01 MF Import
>
Address Records
>
COMMERCIAL AVE
>
6307
>
6307 COMMERCIAL AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2017 11:58:15 PM
Creation date
2/11/2017 11:57:58 PM
Metadata
Fields
Template:
Address Document
Street Name
COMMERCIAL AVE
Street Number
6307
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,. _ -. <br /> Plan Check M48082 <br /> August 10, 1995 <br /> Page 2 <br /> � 5. The details and cross-secdon show post and beam construction. Provide <br /> fr�undation plan showing girders and floor joists if you plan to use floor joisu or <br /> er,gineered wood I-beam floor system. <br /> 6. Every dwelling unit shall have smoke detectors installed in accordance with the <br /> approved manufacturer's instruction. Detectors shall be installed in all sleeping <br /> rooms and in the corridor or azea giving access to each separate sleeping room a <br /> detector shall be installed on each floor. <br /> 7. Handrails shall be 1 1/4" - 2" in diameter and placed min. 34", 38" max, above <br /> tread nosing. Ends shall be returned or terminate in newel post or safety <br /> terminal. � <br /> 8. Provide roof framing plan (may b� shown on floor plans). <br /> 9. Provide floor framing plan for second�floor. Show all headers in bearing walls. <br /> Trace all loads to the foundation. <br /> 10. The plans show different type of construcdon for the same walls. One detail <br /> shown 2 x 6 construction with R-19 insulauon, another sho x 4 cons ' I <br /> with R-11 insulation. Clarify all conflicts in plans. Delete all notes, details, <br /> and drawings that are not applicable to this project. <br /> I1. Provide detail of attic ventilation type, size and locadon. Show the required net � <br /> area calculadons assuming approximately 753'0 of the vent azea is net area unless <br /> the actual net area is given from the manufacturer. <br /> 12. Insulated baffles shall extend b" vertically above batts and 12" vertically above <br /> loosefill insulation. <br /> 13. Provide detail of foundation. . Show size and spacing of anchor bolt and show <br /> min. requirements for reinforcing steel in foodngs and stem wall. <br /> In order for the processing of your application to condnue, it will be necessary to <br /> provide the Building Division with two complete new sets of drawings reflecdng the <br /> corrections requested. <br /> i 1 <br /> I S <br /> I � <br />
The URL can be used to link to this page
Your browser does not support the video tag.