Laserfiche WebLink
. - � i <br /> 7. Below grade walls in conditioned spaces are required to be insulated on the exterior with <br /> R-10 rigid insulation (must be able to verify placement) or R-21 insulation on the <br /> interior. <br /> 8. The structural calculations indicate that some of the CMU walls will be supported out of <br /> plane by slabs on grade, possibly by a FAP plate? Please clarify with a detail and <br /> spacing requirements. <br /> 9. Please provide material specifications for all concrete, ChiU, grout, and reinforcing steel. <br /> 10. Please provide reinforcing steel spacing requirements to meet the structural or minimum <br /> ACI codes (vertical and horizontal). <br /> 11.All structural provisions should be included within the structural documents, including <br /> the apparenUy special case at the media closet and any other requirements that are in <br /> the structural report only. <br /> 12. Specify square footage of basement addidon. Include structural walls in total. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> ���� <br /> ]eff Heilman <br /> Development Technician <br /> 425-257-8976 <br /> Email: jheilmanC�ci everett.wa.us <br /> � <br />