Laserfiche WebLink
rapid enlry system may also be desirable in order to avoid unnecessary damage <br /> while making entry to any building during an emergency situafion. <br /> 45. Fire lanes shall be provided as reGuired in Everett Municipai Code 46.44. Fire <br /> lanes shall be identified by red curbs with white stenciling stating "NO PARKING <br /> - FIRE LANE" and vertical signs siating "NO PARKING - FIRE LANE -TOW <br /> AWAY ZONE' Location shall be approved by the Fire Marshal. <br /> 46. Any security fence erected around lhe construction site shall be located so as to <br /> not obslruct any existing hydranl, fire protection equipment, or Fire Depariment <br /> access. If Fire Department access is obstructed, gates or other openings shall <br /> be provided for access. <br /> 47. r'remises shall be clearly idenlified by the correct address al ihe sireet entry. <br /> Buildings shall be clearly identified so as io be visible and legible frorn lhe access <br /> road. Individual apartmenls and suites, where applicable, shall be clearly and <br /> legibly identified from the access road. <br /> 48. Premise idenlification and all required Fire Deparlment access roads and fire <br /> hydrants shall be in service prior to commencement of construction. <br /> 49. 7he Everell Municipal Code and Ihe Inlernalional Fire Code require that fire <br /> hydranis be provided within a maximum distance and of sufficfent number and <br /> spacing to all new construc6on. The distance and number oi hydrants varies <br /> based on type of consiruction and occupancy of the structure. <br /> 50. A fire hydrant is required within 200 driving feet, but not doser than 50 feet, of <br /> every slructure. Lo�ation of lhe hydrant(s) shall be approved by lhe Fire <br /> Marshal. <br /> 51. MSRC Buildinq-When the required fire ilow is over 2,500 gpm, the fire hydrant <br /> shall be served by a main Ihal loops around the building or complex of buildings <br /> and reconnects back into a distribution supply main. <br /> 52. Based upon 56,500 square feet of Type V-5, sprinklered construclion, Ihe fire <br /> flow requirement is 3,250 gpm. <br /> 53. n portable fire exlinguisher with a minimum U.L. raling of 2-A:10-B:C shall be <br /> prowded Hnthin 75 feet of iravel on all iloors of each building during construcUon <br /> and prior lo occupancy. <br /> 5l. Garaaes (MSRC Buildinq)- Install a portabie fire extinguisher wilh a minlmum <br /> U.L. rating of 2-A:40-B:C within 30 feet Iravel distence of all portions of this <br /> building. <br /> 55. An approved aulomatic iire detection system shall be provided in all buildings as <br /> required by City Ordinance No. 1902-92, Chapler 16.76, of the Everetl Municipal <br /> Code. Plans for such system shall be submitled to the Fire Marshal fw review <br /> and approval prior to inslallation. Submitial shall include cut sheets of all <br /> equipment intended for use. Appropriate trip tests, witnessed by a Fire <br /> Department inspector, shall be pertormed, along with a certificate of completion, <br /> prior to final acceptance of the system. Fire alarm systems shall be Installed <br /> according to NFPA Standard 72. Inslallalion of fire alarm componenls, induding <br /> 2,�a3 <br />