My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1205 CRAFTSMAN WAY SCUTTLEBUTT BREWING 2016-01-01 MF Import
>
Address Records
>
CRAFTSMAN WAY
>
1205
>
SCUTTLEBUTT BREWING
>
1205 CRAFTSMAN WAY SCUTTLEBUTT BREWING 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2017 4:03:57 PM
Creation date
2/12/2017 12:54:46 AM
Metadata
Fields
Template:
Address Document
Street Name
CRAFTSMAN WAY
Street Number
1205
Tenant Name
SCUTTLEBUTT BREWING
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I i <br /> Sent via e-mail <br /> PL/BL/L ft/O/�/C5 �l a�/�� <br /> February 28, 2011 <br /> Mr. Adam Clark <br /> 281Z Architecture <br /> 2812 Colby Avenue <br /> Everett, WA 98201 <br /> Project: Scuttlebutt Kitchen H�ods, Type I and Type II <br /> Job Address: 1205 Craftsman Way <br /> Plan Review: M1102-026 <br /> � <br /> Dear Adam, <br /> In response to the application for a mechanical permit, the plans have been examined <br /> and you are advised that a permit cannot be issued until the following issues are <br /> resolved. Two set of revised documents are required for plan review to resume. For <br /> clarificakion, please have the engineer cloud and identify any revisions to the drawings. <br /> Type I Hood Review <br /> 1. The listed assembly for the grease duct enclosure system of one hour resistant <br /> grease duct fire v�rap should be shown to meet the requirements of ASTM E 2336 <br /> and as a through-penetration fire� op to meet the requirements of ASTM E 814 or <br /> UL 1479, per IMC section 506.3.6, exception 3. <br /> 2. A plan of the second floor shaR should be shown on the drawings with the <br /> following dimensions: inside clear space of the shaft, Type I hood duct sizes, and <br /> the thickness of the grease duct fire wrap on both Type I hood ducts, per IMC <br /> section 506.3.10.1. <br /> 3. The start and termination of the grease duct fire wrap for the Type I hood ducts <br /> should be shown on building sections (sheets M6 and M7) to extend from the Type <br /> I hoods to the outlet terminal, per IMC Section 506.3.10.2. <br /> 4. The kitchen ceiling height should be shown on the shown on the building sections <br /> (sheets M6 and M7). Where the kitchen ceiling abuts the Type I hoods, 18 inches <br /> of a smooth, cieanable, nonabsorbent and noncombustible material should be <br /> shown on the drawings between the hood and the ceiling material, per the <br /> exception to IMC section 507 �. <br /> 5. The location of the two Type I hoods and the Type II hood should be identified <br /> with arrow-headed notes on sheets K-1 and K-5. Where the Type I hood ahuts <br /> the wall, a smooth, cleanable, nonabsorbent and noncombustible material should <br /> be shown on the drawings and noteci to extend 18 inches in all directions from the <br /> hood to the full height of the hood canopy, per the exception to IMC section <br /> 507.9. <br /> , <br /> 1 <br /> i <br /> EIJGINEERING I PUBLIC SERVICES DIVISION • 3200 Cedar Street• Evcrett,WA 982f11 •(425)257-8000• Fax(425)257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.