. � <br /> ..�;� <br /> � <br /> Plan Check No. B-421g3 <br /> October 12, 1993 <br /> Page Two of Two <br /> 10. Exits are req�;red to have a minimum separation of one-half the maximum diagonal of the <br /> • building or area sen,ed measured in a straight line between exits. Secdon 3303(c). <br /> 11. No point in the building may be more than 150 feet from an eaterior exit, horizontal <br /> exit, enclosed stairway, or exit passageway. <br /> 12. Every required exit doorway shall be of a size to permit the installadon of a 3'0" x 6'8" <br /> door. A minimum clear width of 32 inches must be provided, Secdon 3304(�, <br /> 13. Revolving, sliding and overhead doors are not permitted as exit doors when serving <br /> hazardous azeas or an occupant load of 10 or more. Sec6on 3304(h). <br /> 14. A floor or landing not more than �h" be]ow the threshold is required on each side of an <br /> ezit door. Section 3304(i). <br /> 15. Landings shall have a width not less than the width of the stairway or the width of the <br /> door, whichever is greater. Section 3304(j). <br /> 16. The length of the landing measured in the direction of travel shall be not less than 44 <br /> inches. Secdon 3304(j). <br /> In order for the processing of your application to continue, it will be necessazy co pr���de the <br /> Building Division with two complete new sets of drawings refleccing the correcuons requested. <br /> Upon resubmittal of the drawings, your applicaGor will be given priority and plan review <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient informadon to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes, <br /> Sin , <br /> � � <br /> S. M all <br /> Associate Engineer/Building <br /> isM:�Bia�i�r.� <br />