COMPLIANCE <br />REQUIRED V <br />H <br />n <br />0 <br />C <br />INSPECTION <br />APPRovED IMPORTANT: Please supply Information In the shaded boxes and check the appropriate <br />circles. Disregard topics that don't describe your building or equipment. DO NOT place <br />checks In the two left columns. <br />,i� <br />a r <br />❑ © Exterior slab Insulation, it not located on the interior, shall be R-10 (Table 6.2). <br />❑ Q Exterior slab insulation, it present, shall approved for below grade use and protected above grade. <br />❑ zUe Wails, including rim joists, shall be insulated without compression to (Table 6-2): <br />OR-15 batt (Options 1,11) OR-19 (Option III, IV, V, Vi, VII) <br />❑ z9 Interlor below grade walls shall be insulated without compression to (Table 6.2): <br />OR-15 (Options 1, II) R-19 (Options III, IV, V. VI, VII) <br />❑ QVaulted ceilings shall be insulated without compression to R-30 (Table 6-2, All options) <br />❑ IQ Skylight wall Insulation is installed and equivalent to the required wall R-values above. <br />❑ 0 Vapor retarders shall bp Installed toward the warm surface as represented below (502,1.6): <br />Select one option for,,ours, walls, and appropriate ceilings:`` <br />Floors: 0,Plywood.W/ exterior glue 0 Poly (> 4 Mil) O Backed batts <br />Walls: Poly plastic (a 4 Mil) 0 Face -stapled, backed batts 0 PVA paint <br />Ceilings: Not required where ventilation space averages >12" above insulation, <br />Face stapled jacked batts Q Poly plastic (z 4 mil) 0 PVA paint <br />❑ Heating system off [Clancy and sizing requirements shall be met as represented below: <br />El8 Heat Pump efficlency shall be met under the following compliance path (S. 503.4): <br />0 Split system, air source heat pump: HSPF a 6.8, COP > 3.0 <br />0 Single package, air source heat pump: HSPF> 6.6, COP > 3.0 <br />Q Water source heat pump: CCP a 3.8 <br />0 Ground source heat pump COP a 3.0 <br />❑ Q central force•air furnsco AFUE rating, as listed in the GAMA Directory, shall be:. <br />Q> .78 (Options I, 11, IV, VI, VII) O a .88 (Option IIq) Q = 74 (Option V) <br />❑ e Non -central, combustion heating systems shall have intermitent ignition <br />El�7]Maximum heating system output (150%of design heat load) is 4z-7-02 BTUihr. (S. 503.2.2) <br />❑ s��1s High efficiency forced -air furnace (s 56,000 BTU/hr. outpugmay may exceed 1500/cofDHL <br />because: OGAMA listed AFUE is.-- 78 + 1 per each 5000 BTU/hr output that it exceeds the DHL. <br />�IhSEC Insulation phase requirements: <br />Inspected by: Date <br />❑ E) Envelope Floors shall be insulated without compression, and with supports 24" O.C. to: <br />OR1 s (Options 1, II, ill, IV, V) O R25 (Options VI, VII) <br />❑ Eo Non -vaulted, attic ceilings shall be Insulated without compression to: <br />C)R-30 (0 t1ons 1, II, III, IV, V, VII) 0 R38 (Option VI) See Table 6-2 <br />❑ Q Door systems shall meet:Q,U.40 (All options) <br />Door types are (1)L ..., .. a l2) 13a," sj_ 1) 3 <br />Page 5 of 6 <br />