My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 EVERETT AVE 2016-01-01 MF Import
>
Address Records
>
EVERETT AVE
>
2001
>
2001 EVERETT AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2018 10:20:01 AM
Creation date
2/12/2017 7:24:24 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERETT AVE
Street Number
2001
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Subject: Proposed Remodel of McDonald's of Everett, 2001 Everett Ave, Everett <br /> January 15, 2013 <br /> Page 2 <br /> Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks <br /> and at the same time provide hot water to all handwash sinks. <br /> 10. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br /> must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br /> inspection. This is required so that proper testing of the 15-second time requirement for hot water <br /> availability can be completed. <br /> 11. Ail food service equipment, both new and used, must be listed by the National Sanitation <br /> Foundation (NSF) or equivalent for its intended use. Used and new reirigeration must be capable of <br /> holding food at temperature of 41°F or below. <br /> 12 fo d servUicem stablishm�e ttUsedlequipmanit mustbeecean, n proper�lope atir,g condition�and in <br /> good repair. Used refrigeration must be capable of holding at a temperature of 41°P or below. <br /> 13. Extra wail protection is required on walls behind all sinks, including restroom handwash sinks, and <br /> food preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass- <br /> reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall <br /> behind counter top equipment taller than 16 inches. Floor to ceiling protection is required on the <br /> wall behind dishwashers. Wall protection behind mop sinks must cover the entire splash zone. <br /> Plastic coated hardboard is not acceptable. <br /> 14. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must <br /> be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br /> cuts and the like in concrete floors in ail areas, including customer seating areas, must be filled and <br /> sealed so as to provide a smooth and cleanable surface. <br /> 15. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br /> easily cleanable. <br /> 16. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type <br /> surfaces are not acceptable) <br /> 17 shatterproofrbuibsf Hot ho d urnit heat amps mu trbe p ov ded with hatter�proof bulbsnd <br /> 18. Plumbing must meet state and local codes. <br /> 19. The ventilation system shall be installed and operated to meet applicable building, mechanical, and <br /> fire codes. <br /> 20. Please note that failure to schedule a preoperational inspection prior to reopening for <br /> business following a remodel may invalidate your food service establishment operating <br /> permit. <br /> A preoperational inspection is required prior to reopening for business. At the time of inspection <br /> the construction of the food service estab!ishment must be complete and all equipment must be in <br /> place and in proper operating condition. Incomple+e construction or eqwpment operation will result in a <br /> 5168.00 re-inspection fee. Contact the Food Program office a minimum of one week in advance of <br /> the desired inspection date to schedule an apnointment for the preoperational inspection. The <br /> preoperational inspection will ensure compliana� with the Rules and Requlations of the State Board of <br /> Health for Food Service Sanitation. <br />
The URL can be used to link to this page
Your browser does not support the video tag.