My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1000 SE EVERETT MALL WAY BASE FILE 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
1000
>
BASE FILE
>
1000 SE EVERETT MALL WAY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2019 8:19:18 AM
Creation date
2/13/2017 6:55:29 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1000
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check ll2.7- <br /> Larry Callahan <br /> Au9ust 9, 1985 <br /> Page Five <br /> h. Column struts between frame coluinns ai�e provided for all frames <br /> except "frame 7". They should be provided for that frame as well . <br /> 5. Ductile moment resisting space frames: <br /> a. Welded connections betwe�n primary members of the ductile moment-resist- <br /> ing space frames should be tested by nondestructive methods for com- <br /> pliance with UBC Standard 27-6. The test program should be established <br /> by the engineer-of-record and shown on the plans and specifications. <br /> The program should include the minimum requirements in Section 2722(f). <br /> The requirements should be shown on the plans and specifications. <br /> b. In order to qualify as a moment resisting space frame unde�• the defini- <br /> tion of Section 2312(b), all columns should have a joist, bezm or <br /> girder framing into them in two perpendicular directions at each floor. <br /> IJhere joists line up with columns, their connectiun to the column <br /> should be detailed to insure that nominal moment resistance is achieved <br /> at all joints. Where joists do not line up with columns, such as grid <br /> D-7 on Sheet 5-4, a member siiould be added. <br /> c. The connection between beams & columns in the ductile frames(Detail 4/S-7) <br /> should develop the full plastic moment capacit,y of the beams. Section <br /> 2722(d). This cannot be achieved by welding only the beam flanges <br /> to the columns. In lieu of this , calculations must demonstrate that <br /> adequate ductile joint displacement capacity can be developed with a <br /> lesser connection. Section 2722(d), exception <br /> d. The shears in many of the panel joints of the ductile frames, and in <br /> many of the doubler plates where they are provided, exceed the allow- <br /> able shear in equation 21-5 of Section 2721. <br /> e. The conneciions between the duct�le columns and roof girders should be <br /> detailed. Section 302(c). The typical fioor 9irder-to-column details <br /> do not apply at the roof. <br /> 6. hl�mbro composite floor system: <br /> a. "Hambro" �omposite steel joist and concrete deck floor systems are <br /> proposed for the building. See Evaluation Report PFC-2869. You <br /> could if you wish, accept this systzm under Section 105. <br /> b. If the systems are proposed to achieve a fire resistive floor/ceilin9 <br /> assembly, the project specifications should clearly outline the method <br /> of installation, to verify coinpliance with said report. Note that <br /> ceiling runners are required in 2 perpendicular directions for the <br /> proposed joist spacings. <br />
The URL can be used to link to this page
Your browser does not support the video tag.