Plan Check 172� <br /> Larry Callahan <br /> Au9ust 9, 1985 <br /> Page Four <br /> e. I:eferring to the retaining wall section on Sheet S-1, Chapter 14 of the <br /> CRSI Handbook recommends placement of dia9onal bars at the back of <br /> the base of the wall stem to resist the tension crack between the ;tem <br /> and the vertical reinforcing. <br /> f. Referi•ing to Cetail 6/S-1, corrosion protection of the exposed struc- <br /> tural steei �nembers should be sper,ified. Section 2607(h). Carbon <br /> content or r;Aldable reinforcing bars should also be specified. Sec- <br /> tion 2603(f) and 26-8 UBC Standard <br /> 4. Concrete columns and footings below ductile frames: <br /> a. The 24" x 30" concrete columns, supporting the steel columns of the <br /> ductile moment frames, should be detailed as ductile columns. Section <br /> 2312(j)1.I <br /> b. Closed tie sp�cin9 for these columns, in the top and bottom 30" of the <br /> column height should not exceed 4". Section 2625(f)4.A. The cross <br /> sectional area of the ties should be computed from Equation 25-4. <br /> c. Dovrels matchin9 the vertical reinforcing o:` these columns should be <br /> specified for connection to be footings below, and should extend <br /> high enough into the columns to lap a minimum of 30 bar diameters <br /> within the middle 1/2 of the column height. Section 2625(f)3. <br /> Dowel embedment and hook dimensions in the footings should be shown to <br /> develop the bars. <br /> d. In the footin9s themselves below these columns, closed ties should be <br /> provided around the flexura', reinforcing. Section 2607(1 ) <br /> e. The anchor bolts between the ductile steel columns and supporting <br /> concrete columns are detailed on Sheet S-7. These anchor bolts are <br /> as large as 2" in diameter in some cases but are placed near the <br /> corners of the columns. The adequacy of the concrete shear cones <br /> should be justified by calculations. Section 2303(b) <br /> f. The 3/8" x 4" square plate washers on these anchor bolts have a <br /> bearin9 pressure �t the concrete-to-steel interface as high as 14 ksi. <br /> The adequacy of the stress transfer between the steel and concrete <br /> should be justified by calculations. <br /> g. The ability of the footings to transfer the frame moments to the support- <br /> ing soils, as considered in the submitted calculations, was based solely <br /> on load cnmbination equation 9-2 of Section 2609(c). However, equation <br /> 9-3, i .e. relying only on the dead load of the structure (not live loads) <br /> to resist the overturning moments, will govern the design. <br />