My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1130 SE EVERETT MALL WAY BLDG 3 SHELL 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
1130
>
BLDG 3 SHELL
>
1130 SE EVERETT MALL WAY BLDG 3 SHELL 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2019 8:29:27 AM
Creation date
2/13/2017 7:21:34 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1130
Tenant Name
BLDG 3 SHELL
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Everelt Mall Building 3 Shell F. ..kage <br /> 11/1/C6 <br /> Page 3 of 3 <br /> 10. The drawings for the support of the glass are not sufficiently detailed to specify installation of <br /> glazing with an unsupported edge, per IBC 2403.2 and 2403.3. the c�lazing materials should be <br /> indicated on the drawings to meet the requiremenls of IBC 2405.2. Screens are required for the <br /> height of the glazing indicated on Section 5/a5.01, per IBC 2405.3. All storefront glazing panels <br /> parallel and adjacent to doors (with the lowest edge less than 60 inches from lhe walking surtaces) <br /> are required to be lempered per IBC 2406.3. <br /> The canopy details have been revised. The glass type has been noted as '/:" laminafed glass <br /> per IBC 2405.2. With this type of glass, screens are nut requirod as noted in 2405.3. Only <br /> hcat strengthen glass and fully tempsred glass shall have screens. The details have been <br /> revised to reflect a mullion type system as opposed to the pin mount glass. This detail is <br /> based upon the existing canopy on the Mall entry. The specification require shop drawings <br /> and calculations be provided. See sheot A06.10. <br /> 11. Dissimilar melals indicaled in the buildings canopy extending through the masonry wall (seclions 5 <br /> & 13/A5.01) should be isolaled to minimize galvanic corrosion, per IBC 2t03.11.7. <br /> Notes havc been added to sheet A06.10 indicatiny that the steel needs to be hot dipped <br /> c�alvanized per IBC 2103.11.7. <br /> 12. Special Inspeclion are required for EIFS cladding per IBC 1704.12. <br /> A note has been added to A4.01 and A4.02. Inspection is not required over CMU <br /> applications. Also inspection is not required for systems that are installed over water- <br /> resistive barrier with a means of drainago. Our current system in our specifications <br /> provides for theso items and in the note we indicata that if the system does not provide tliis, <br /> the an inspection is required per IBC 1704.12. <br /> 13. The insulation indicaled on the roof and at the slab on grade for detail 17/a5.02 should be <br /> identi(ied on the drawings and demonstraled in supporting material lo meet on of the optiens for <br /> the building envelope compliance identified in WSEC figure 13.A. <br /> The insulation R-Values have been indicated on the drawings sheet A5.01 and A5.02. These <br /> have been calculated based upon "Perspective Requirements" as laid out in the WSEC. We have <br /> indicated this on G01.01 as well as the Qneryy type. <br /> 14. The vault or sprinkler room should be indicated on Ihe shell building drawings to meel the <br /> requirements of the Ciry of Everett Public Works Double Check Detector Valve Assembly Drawings <br /> 515, �16 or 523. <br /> We have indicated the location of the voult on sheet A01.10 and type of vault. <br /> i �3> <br /> `, <br />
The URL can be used to link to this page
Your browser does not support the video tag.