My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
35 SE EVERETT MALL WAY BASE FILE 2018-01-02 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
35
>
BASE FILE
>
35 SE EVERETT MALL WAY BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2022 2:33:17 PM
Creation date
2/13/2017 8:21:21 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
35
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fire alarm systems shall be installed under permit of the City of Everett Building Department. <br />Electrical inspections and approval are required prior to calling for acceptance tests. Call (425) 257- <br />8810 for permit information. <br />The absence of working phone lines for the alarm sy.:tem will be cause for postponing fire <br />department inspection and testing and shall result in denial of occupancy. <br />10. Fire Suppression (Sprinkler) System (Retail Building) - An approved automatic suppression system <br />shall be provided as required by City Ordinance No. 1902-92, Chapter 16.76, of the Everett <br />Municipal Code. The system must include a mechanical water gong bell. <br />Plans for any such system shall be submitted to the Building Department for examination and <br />approval. Such plans shall include plans for the underground mains that will supply the sprinkler <br />system. <br />The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA <br />13, NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler installation shall <br />not begin without an approved and stamped set of plans from the Building Department. The <br />Fite Department will also review the plans and shall field inspect the installation based only on <br />approved plans that must be on site. Changes to plans must be approved by both the Building and <br />Fire Departments. <br />Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br />Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 <br />for private fire mains. (Below -around piping must be installed by Washington State Patrol <br />Licensed Underground Sprinkler line certified "U" installers. For further information, contact <br />the State Fire Marshal's Office at (360) 570-3134 or contact the Everett Fire Department at <br />(425) 257-8125. All such tests shall be witnessed by a Fire Department inspector. Call (425) 257- <br />8124 to make an appointment for inspection. <br />Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to <br />issuance of any Certificates of Occupancy. <br />Call (425) 257-8125 for more information. <br />11. Construction and demolition of buildings shall be in compliance with the provisions of the 2003 <br />International Fire Code, Chapter 14. <br />12. Permits are required from the Fire Department for removal and installation of underground fuel <br />tanks. <br />13. Abandoned tanks shall be pumped out and the heel properly disposed of prior to removal. No <br />product or rinse water may be disposed of in such a way that it could enter the storm drains system. <br />14. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or closets with <br />standard man door access. Locations shall be approved by the Fire Marshal's Office. <br />If the man door acce <br />location to be deterrc <br />an-NFPA 13 system. <br />
The URL can be used to link to this page
Your browser does not support the video tag.