My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
35 SE EVERETT MALL WAY BASE FILE 2018-01-02 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
35
>
BASE FILE
>
35 SE EVERETT MALL WAY BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2022 2:33:17 PM
Creation date
2/13/2017 8:21:21 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
35
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2006 ' ington State Nonresidential Energy Code Cor( 7nce Form <br />\1 <br />Building Permit <br />2006 Wm asngion stale Nonresdental Energy Code Conplianw Foma Revised July 200r <br />Project Address 31. SE evoaett nail way, rot 2 <br />Dale 9/6/2007 <br />The following information is necessary to check a building permit application for compliance with the building envelope requirements in <br />the Washington State Nonresidential Energy Code. <br />Applicability <br />Code <br />Location <br />Building Department <br />(yes, no, n.a.) <br />Section <br />Con oonent <br />Information Required <br />on Plans <br />Notes <br />GENERAL REQUIREMENTS (Sections 1301-1314) <br />1301 <br />ScopeUnconditioned <br />spaces identified on plans it allowed <br />yea <br />1302 <br />Space heal type' <br />^o' <br />Indicate <br />II "Olhef', <br />on plans that electric resistance heal is not allowed <br />yes <br />1310.2 <br />Semi -heated spaces <br />Semi -heated spaces identified on plans If allowed <br />A2, e <br />1371 <br />Insulation <br />yea <br />1311.1 <br />Insul. installation <br />Indicate densities and clearances <br />1311.2 <br />Roof /ceiling Instill. <br />Indicate R-value on roof sections for allies and other roofs; <br />Indicate clearances for attic insulation, <br />Indicate battles if cave vents installed. <br />Indicate face stapling of faced balls <br />ynn <br />1311.3 <br />Wall insulation <br />Indicate R-value on wall sections; <br />Indicate face stapling of faced bails, <br />Indicate above grade exterior Insulation is protected; <br />Indicate loose -fill core insulation for masonry walls as access; <br />Indicate heat capacity of masonry walls <br />If masonry option is used F73' <br />.,. <br />13114 <br />Floor insulation <br />Indicate R-value on floor sections, <br />Indicate substantial contact with surface, <br />Indicate supports not more than 24' o.c ; <br />Indicate that insulation does not block <br />airflow through foundation vents <br />. <br />y: <br />1311.6 <br />Slaben-grade floor <br />Indicale R-value on wall section or foundation detail, <br />Indicate slab insulation extends down vertically 24" from lop; <br />Indicate above grade exterior insulation is protected <br />1311.6 <br />Radiant floor <br />IndicateR.value on wall section or foundation detail: <br />Indicate slab insulation extends down vertically 36" from the top; <br />Indicate above grade exeror insulation Is protected, <br />Indicate insulation also under entire slab where read by Official <br />yun <br />1312 <br />Glazing and deals <br />Provide calculation of glazing area (including both vertical <br />vertical and overhead) as percent of moss wall area <br />1312.1 <br />Udactors <br />Indicate glazing and door U-factors on glazing and door <br />schedule (provide area -weighted calculations as necessary), <br />A2. o <br />Indicate If values am NFRC or default, if values am default <br />then specify frame type, glazing layers, gapwidth, lowe <br />coatings, as fillings <br />1312 2 <br />SHGC 3 SC <br />Indicate glazing solar heat gain coefficient or shading <br />Az. e <br />coefficient on glazing schedule (provide area -weighted <br />calculations as necessa <br />1313 <br />Malslure control <br />yoe <br />1313.1 <br />Vapor retarders <br />Indicate vapor retarders on warm side <br />Y.. <br />1313.2 <br />Roof/ceiling vap.mt. <br />Indicate vapor retainer on roof section; <br />Indicate vap retard. with sealed seams for non -wood sbuc. <br />Yes <br />1313.3 <br />Well vapor retarder <br />Indicate vapor retarder on wall section <br />a.a <br />yoe <br />1313A <br />Floor vapor retarder <br />Indicate vapor retarder on floor section <br />A°' - <br />a.: <br />in.a. <br />1313.5 <br />Crawl space vap. ref. <br />Indicate six mil black polyethylene overlapped 12" on ground <br />1314 <br />Air leakage <br />yes <br />1314.1 <br />Bldgenvel. sealing <br />indicate sealing, caulking, gasketing, and weatherstripping <br />A2. o <br />yoe <br />1314.2 <br />Glazing/door sealing <br />Indicate weatherstripping <br />A2.0 <br />n.a. <br />1314.3 <br />Assembas ducts <br />Indicate sealing, caulking and gasketing <br />n. a. <br />1314.4 <br />Recessed Lighting i <br />Indicate IC rating, ASTM E283 certification, and gasketing or caulking to <br />ceiling <br />PRESCRIPTIVE/COMPONENT PERFORMANCE (Sections 1320-23 or 1330-34) <br />You <br />Envelope Sum. Form <br />Completed and attached. <br />T-E-_ <br />Provide component performance worksheet If necessary <br />If "no" is shaven for any question, provide explanation: <br />0/6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.