Laserfiche WebLink
"� ! SNOHOMISH <br />HEALTH DISTRICT <br />W W W.SNOHD.ORG <br />September 19, 2014 <br />Jody Fox <br />10202 5 Ave NE #300 <br />Seattle, WA 98125 <br />�II .�:�. �c��lf � C',� <br />. v � <br />I <br />PUBLIC �'��KS <br />Subject: Proposed Remodel Starbucks #2921, 515 SE Everett Mall Way, Everett <br />Dear Mr. Fox: <br />Your plans have been reviewed with the Rules and Requlations of the State Board of Health, and with the <br />policies of the Snohomish Health Disirict. With the addiiion oF the following conditions, the pians ara <br />approved. <br />1. The conditional approval of the plans for Starbucks #2921 was based upon the plans submitted <br />September 15, 2014. Any changes to the plans submitted September 15, 2014 will void this <br />approval. <br />2. Based on information received on September i6, 2014, the back bar handsink is ffteen inches wide <br />with eight inch spiashguards on each side of the handsink. <br />3. Three-compartment sinks must be NSF or equivalent listed with integral drainboards at both ends. The <br />basins of the three-compartment sink must be large enough to fit the largest item needing to be washed. <br />4. An indirect waste drain (an air gap) is required for the three-compartmeni sink, mechanicai dishwasher, <br />ice machine, running water dipper well, and any equipment in which food is placed. Please note that a <br />direct drain to a grease trap is not considered an indirect drain even i; the greas2 trap is indirectiy <br />drained. <br />5. A horizontai separation of at least 16 inches or a vertical partition 16 inches in height is required <br />between the handwash sink and all food preparation areas. <br />6. Water heaters must be of su�cient size to provide hot water lo dishwasher andlor scuilery sinks and at <br />the same time provide hot water to all handwash sinks. <br />7. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility must <br />not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection. <br />This is required so that proper testing of the 15-second time requirement for hot water availability can be <br />completed. <br />S. All food service equipmzr�t, both new and used, must be listed by the National Sanitation Foundation <br />(NSF) or equivalent for its intended use. Used and new refrigeration must be capable of hplding food at <br />temperalure of 41 °F or below. <br />9. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food <br />service establishment. Used equipment must be clean, i� proper operating condition, and in good repair. <br />Used refrigeration must be capable of holding at a temperature of 41°F or below. <br />10. This facility has a limited amount of reach-in refrigeration equipment. No advanced preparation of foods <br />that require cooiing will be allowed unless a walk-in refrigerator or blast chiller (rapid temperature pull <br />down refrigerator) is installed or other Health District approved cooling method is in place. Approval of <br />cooling methods other than in a walk-in refrigerator must be approved prior to final plan approval. Any <br />proposed cooling melhod must be included in required description of the food preparation process. <br />Please note that if any approval for cooling of food is given the risk classification for the establishment <br />3020 Rucker Avenue, Suite 104 r Everett, WA 98201-3900 e tel: 425.339.5250 � fax: 425.339.5254 �/3 <br />