Laserfiche WebLink
SUbjcCt: P�upGScd Rc�od2� StafbuCkS .".2921, 515 S� 5v2�2� Ma11 VVay, Ev2t2N <br />September 19, 2014 <br />Page 2 <br />wiil change to a high-risk food establishment and an additionai permit fee for lhe classification change <br />will be charged. <br />11. Extra wali protection is required on walls behind all sinks, including restroom handwash sinks, and food <br />preparetion counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass-reinforced <br />plastic or equal is acceptable. A backspiash higher than 16 inches is required on the wall behind counter <br />top equipment taller than 16 inches. Floor to ceiling protection is required on the wall behind <br />dishwashers. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated <br />hardboard is not acceptable. <br />12. Ail floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be <br />surfaced with a durable, nonabsorbent, easily cieanabie material. Expansion joints, seams, saw cuts and <br />lhe like in concrete floors in all areas, including customer seating areas, must be filled and sealed so as <br />to provide a smooth ar�d cleanable surface. <br />13. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and easily <br />cieanable. <br />14. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Seif stick vinyl or other type <br />surfaces are not acceptable) <br />15. All light fixtures in food preparation and storage areas must be provided with covers and shatterproof <br />bulbs. Hot hold unit heat lamps must he provided with shatterproof bulbs. <br />16. If the establishment continues to be in operation during the remodel, dust barriers must be installed to <br />ensure that food protection and safety is not compromiszd. The astablishment will be required to <br />discontinue operations if any disruption in water, electrical, or sewer service occurs, due to the remodel. <br />Proper handwash stations must be kept accessible and functional during all hours of food service <br />establishment operation. <br />17. Plumbing must meet state and local codes. <br />18. It cannot be determined from the floor plan or information submitted whether or not a chemical <br />dispensing system will be installed at the mop sink. Please note that the use of screw-on type'wye' <br />adaptors at the mop sink faucet for use with chemical dispensing systems is prohibited. Additionally <br />chemical dispensers cannot be connected to the mop sink faucet. The chemical dispenser must have a <br />separate evater connection. A'sidekick' adaptor at the mop sink faucet is acceptable. <br />19. The ventilation system shall be installed and operated to meet applicable building, mechanic2l, and fire <br />codes. <br />A preoperetional inspection is required prior to operating permit issuance and approval to open for <br />business. At the time of inspection the construction of the food service establishment must be complete and <br />all equipment must be in place and in proper operating condition. Incomplete construction or equipment <br />operation will result in a 5168.00 re-inspection fee. Contact the Food Program office a minimum of one <br />week in advance to schedule an appointment for the preoperational inspection. The preoperational <br />inspection will ensure compliance with the Rules and Rectulations of the State Board of Health for Food <br />Service Sanitation. <br />