My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 SE EVERETT MALL WAY AA CHINA BUFFET 2016-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
AA CHINA BUFFET
>
607 SE EVERETT MALL WAY AA CHINA BUFFET 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2017 6:38:54 PM
Creation date
2/13/2017 8:31:10 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
AA CHINA BUFFET
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I'xf-Q-� � �� D.6 <br />P.O. IIOX 28404 SmtUc, WA 98118 <br />Date: May 5, 2006 <br />Meg M. Haley <br />Plans Examiner <br />City of Everett <br />Subject: Responsc to dic Building Permit Plan Review For the project located at <br />607 SE Everett Mall Way <br />(Plan Review No. B0604-047) <br />Dear Meg: <br />In responsc to your review wmments made in May 2, 2U06, ::nd I am providing the following: <br />1. Clarificd the differentia from new construction and existing construction (sec sheet Al, Floor <br />Plan Layout). <br />2. Specificd the fire separation wall not remove (see shcet Al, Floor Plan Layout). <br />3. Providcd a licensed architect to prepare construction documenLs for the project (see sheet A1 and <br />A2, licensed architect stamp). <br />4. Noted the glazing in swinging doors should be tempered glass (sec shcet Al, Floor Plan Layout). <br />5. Reviscd Uie main entrance doors swing out (see sheet A1 and AZ). <br />6. Providcd the exit signs on thc two means of egress from thc both dining azeas (noted on shcet Al <br />and A2). <br />7. Provided illumination and tacGle cxit signs (showed on sheet A2, Equipment Layout Plan). <br />8. No new emcrgency egress lighting. <br />9. Clarificd thc men's room accessible stall door to swing out and provided minimum clear <br />dimcnsions (see sheet A1 and A2). <br />10. Clarificd the accessible urinals be a required space for wheelchair access (see sheet A1 and A2). <br />I 1. Specified the buffet equipment and layout should be accessible (see sheet A2, Equipment Layout <br />Plan and Obstructed High Sidc Reach dctail). <br />12. No removal in the Men's Toilct. <br />13. The building owner verified the employce toilet room was not used by an adjacent building <br />tenant. <br />14. Notcd the new equipment will be rcquire a new fire suppression submittal for the Type I Hood <br />(noted on sheet A2, Equipment Layout Plan). <br />Attached you �vill find t�vo sets of revised with the above required revisions. <br />If you have any questions or comments, please call me at (206) 229-5658 or (206) 722-8067. <br />Sincerely, <br />E a Taµm ' ` '�' <br />cvu\comcctionnspons�s�ncgsccrctt <br />
The URL can be used to link to this page
Your browser does not support the video tag.