- ay , <br />Mr. Xue Ta Tang, Tenant c/o <br />Mr. Dave Robinson, Owner <br />Robinson Properties <br />500 SE Everett Mall Way # A7 <br />Everett, WA 98208 <br />Project: AA China Buffet <br />Job Address: G07 SE Everett Mall Way <br />Plan Review No: B0604-047 <br />Dear Mr. Tang and Mr. Robinson, <br />/ PUBLIC SERV/CES DEPARTMENT <br />Thank you, we have received and reviewed the resubmitted documents. Comments from the May 2nd letter <br />which have not been addressed in the resubmitted documents have been noted with a bold heading. <br />In response to the modifications submitted for consh-uction permit, the plans have been examined and you are <br />advised that a permit cannot be issued until the following issues are resolved. These comments address building <br />issues only. Revisions or additions may be required by other departments (such as Utilities, Planning or Pire). <br />Code references cited inciude the 2003 Intemational Building Code (IBC), the 2003 International Mechanical <br />Code (IMC), the Washingion State Energy Code, 2003 edition, and the Accessible and Usable Buildings and <br />Pacilities ICC/ANSI AI 17.1-2003 (ANSI), including amendments by thc State of Washington, and as adopted <br />by the City of Everctt. <br />In order for tLe processing yaur application to continuc, it will bc necessary to provide tLe Building <br />Division with nvo sets of drawings retlecting tlm corrections requcsted. <br />Construction <br />1. Item 1 from previous lctler: this submittal requires a demolition plan of the building envelope and <br />interior to clearly indicate existing construction to be removed and existing conshvction to remain. <br />During the site ��isit today, it was noted that there are several existing conditions which have not been <br />documented accurately, including the men's toilet room, and the multi-tenant egress comdor. <br />2. Item 2 from previous lettcr: The existing one-hour occupancy separation wall and the extent of the <br />one-hour occupancy seoaration wall has neither been noted nor detailed on this submittal. Since this is a <br />required occupancy separafion wall, built in 2004 to expand the area of the A-2 occupancy as it exists <br />today, it should be noted as a one-hour wall on the plans, including the rated ovcrhead door and any <br />other penetrations. Revisions to the existing wall will require additional documentation and detailing. <br />3. The exit corzidor should be a one-hoGr rated corridor F2r IBC Table lO1G.1, including the existing <br />tenant demising walls. <br />4. The door swinging inro the egress corridor should swing in the direcHon of egress, per IBC per IBC <br />1008.1.2. Door swings may reduce the egress corridor by only half of the required �vidth, per IBC <br />1005.2. When fully apen, the door should not project more than 7 inches into the required width, per <br />IBC 1005.2. Prohuding objects should not reduce the minimum cicar width of accessible routes, per <br />IBC 1003.3.4 and 1104. <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-6800 • Fax (425) 257-8856 <br />S�.Utllalcyl\VorJ�060LT1'! W] SG G ven( Alall llby Samnd cortvqion Icue doe <br />