Laserfiche WebLink
� <br />. � <br />SNOHOMISH <br />HEALTH DISTRICT <br />WWW.SNOHD.ORG <br />August 21, 2012 <br />����o��� <br />AUG 2.3 2012 <br />� <br />Melody Thule <br />2612 126�" PI S`N <br />Everett, WA 98204 <br />Subject: Proposed Chamaole Pino Restaurant, 607 SE Everett Mall Way, Everett <br />Dear Ms. Thule: <br />Your plans have been reviewed with the Rules and Reaulations of the State Board of Health, and with the policies <br />of the Snohomish Ffealth District. With the addition of the following conditions, the plans are approved. <br />1. The conditional approval of the plans for Chamaole Pino Restaurent was based upon the plans <br />plans�subm tted August 6 2 12 nd the m nu and HACCPisubrti tted July 18, 2012 will void thise <br />approval. <br />2. The Health District operating permit application process must be compteted prior to opening for business. <br />This facility will be classi�ed as a high risk food estabiishment with 51-150 seats. <br />3. An indirect waste drain (an air gap) is required for the food preparation sink, three-compartment sink, <br />mechanical dishwasher, ice machine, ice bin/sink, steam table, walk-in refrigeration, and any equipment in <br />which food or food contact equipment is placed. Please note that a direct drein to a grease trap is not <br />considered ar� indirect drain even if the grease trap is indirectly drained. <br />4. Each food prPoaration sink must be NSF or equivalent listed with at least one integral drainboard. <br />5. Only one food preparation sink is indicated on the floor plan. Because of this, only vegetable preparation will <br />be atlowed at this sink. No rinsing or thawing under running water of raw meat, poultry, andlor seafood will be <br />allowed without the instaliation of an additional and separate food preparation sink. If installed, the location of <br />any additional food preparation sink must be approved prior to installation. The sink must be NSF listad or <br />equivalent and have at least on integral drainboard. <br />6. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required between the <br />handwash sink item #18 and the mop sink item #17. <br />7. Water heaters must be of sufficient size to provide hot water to dishwasher andlor scuilery sinks and at the <br />same time provide hot water to all handwash sinks. <br />8. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility must not <br />be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection. This is <br />required so that proper testing of the 15-second time requirement for hot water availability can be completed. <br />9 equivalent fo�r ts Int nded use Used and new refrigeration must beh patble of holding fo d�at emperaNure�ofr <br />41°F or below. <br />10. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food service <br />establishment. Used equipmant must be clean, in proper operating condition, and in �ood repair, Used <br />refrigeration must be capable of holding at a temperature of 41°F or below. <br />11. Proper and adequate sneeze protection must be provided at the steam table (item #20) and display <br />refrigerator (item #21) area. The sneeze guard must comply with NSF or equivalent standards. The sneeze <br />protection must intercept the direct line batween the customers mouth and the food preparation area. On <br />average the vertical distance from the customer's mouth to the floor is 4 feet six inches to 5 feet. Additional <br />details are included on the enclosed information sheets. Any alternative sneeze protection methods must be <br />approved prior to the preoperational inspection. <br />3020 Rucker Avenue, Suite 104 � Everett, WA 98201-3900 � tel: 425.339.5250 � fax: 425.339.5254 i I� <br />