My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 SE EVERETT MALL WAY LECHON PALACE 2016-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
LECHON PALACE
>
607 SE EVERETT MALL WAY LECHON PALACE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2017 1:29:57 PM
Creation date
2/13/2017 8:36:40 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
LECHON PALACE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�aecic -woR�rs----- -- -- - - <br />September 27, 2012 <br />Rose/Jose de Jesus <br />607 SE Everett Mall Way, Suite KL <br />Everett WA 98208 <br />RE: Owner: Robinson Properties, Inc. LLC <br />Job Address: 607 SE Everett Mall Way <br />Plan Check No: M1206-031 <br />Dear Ms./Sir: <br />In response to your application for a Type i permit, your plans have been examined and you <br />are advised that the issuance of a permit is being withheld for the reasons listed below. All <br />references refer to the 2009 International Building Code, as amended by the State of <br />Washington and adopted by the City of Everett and the Washington State Energy Code, 2009 <br />Edition, unless stated othenvise. <br />Zn order for the processing of your application to continue, it will be necessary to <br />provide the Building Division with two complete new seLs of construction <br />documents reflecting the corrections requested. <br />1. The submitted document indicates a"stainless wall with 1" pad wall through ceiling." <br />This is insufficient information to verifj� compliance with IMC 507.9. This code section <br />requires a clearance of 18" if the wall contains wood. Please provide a cross sedion <br />through the wall and hood that clearly details all materials and dimensions. <br />2. The same clearance requirements of IMC 507.9 apply at the walls to the sides of the <br />hood. Please provide detailed and dimensional cross sections. <br />3. IMC 507.12 requires the hood to overhang the cooking equipment by 6" on all open <br />sides. Please revise. <br />4. IMC 506.3.12.1 requires fhe exhaust fan discharge opening to be a minimum of 40 <br />inches above the roof surface. This should be indicated. <br />5. IMC 506.3.6 and 506.5.4 require the exhaust equipment to be 18 inches clear of all <br />combustible materials. Please address. <br />6. IMC 506.3.10 requires the exhaust dud to be enclosed. Please address. <br />7. The exhaust capacity is required to comply with IMC 507.13 and 5063.4. Please <br />include. <br />8. The makeup air capacity is required to comply with IMC 508. Please address. <br />9. The hood is required to be provided with grease removal filters in accordance with IMC <br />507.11 and 507.8. Please verify. <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8882 <br />S V Cnmm�,rt.Clmu"S1LIIn'.\II:�M.J I Ib] f.� pLll N��� 1 An[ <br />
The URL can be used to link to this page
Your browser does not support the video tag.