Laserfiche WebLink
Subject: Proposed Le :hon Palace, 607 SE E��erett Mall Way #K-L, Everett <br />January 17, 2014 <br />Page 2 <br />Water heaters mu�t be of su�cient size to provide hot water to dishwasher and/or sculiery sinks <br />and at the same time provide hot water to all handwash sinks. <br />10. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br />must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br />inspection. This is required so that proper testing of the 15-second time requirement for hot water <br />availability can be completed. - <br />11. Ali food service equipment, both new and used, must be listed by the National Sanitation <br />Foundation (NSF) or equivalent for its inlended use. Used and new refrigeration must be capable of <br />holding food at temperature of 41°F or below. <br />12. Used equipment is subject to onsite inspect�on to determine acceptability for use in the proposed <br />food service establishment. Used equipment must be clean, in proper operating condition, and in <br />good repair. Used refrigeration must be capable of hoiding at a temperature of 41°F or below. <br />13. Extra wall protection is required on wails behind all sinks, including restroom handwash sinks, and <br />food preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiterglass- <br />reinforced plastic or equal is acceptablA. A backsplash higher than 16 inches is required on the wall <br />behind counter top equipment tailer than 16 inches. Floor to ceiling protection is required on the <br />wall behind dishwashers. Wall protection behind mop sinks must cover the entire splash zone. <br />Plastic coated hardboard is not acceptable. <br />14. All fioors in the kitchen, food preparation, food service, food storage, and dishwashing areas must <br />be surfaced with a durabie, nonabsorbent, easily cleanable materiat. Expansion joints, seams, saw <br />cuts and the !ike in concrete floors in ali areas, including customer seating areas, must be filled and <br />sealed so as lo provide a smooth and cleanable surFace. <br />15. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br />easily cleanable. <br />16. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Se;f stick vinyl or other type <br />surfaces are not acceptable) <br />17. All light fixtures in food preparation and storage areas must be provided with covers and <br />shatterproof bulbs. Hot hold unit heat lamps must be provided with shatterproof bulbs. <br />18. Plunbirg �TiIJSi iTiEci �iBic oi �u iuCa� CGuc3. <br />19. The ventilation system shail be installed and operated to meet applicable building, mechanical, and <br />fire codes. <br />20. No overnight and or unattended cooking/hot hoiding of any food item is prohibited without <br />proper temperature monitoring equipment and pre-approval of the coi�king and monitoring <br />processes by the Health District. A revised HACCP and the specific type of temperature <br />monitoring equiprnent for any overnight and or unattended hot hoiding must be submitted to <br />the Health Dist: ict for approval prior to any overnight and or unattended cooking. <br />21. No catering will be allowed without preapproval of the menu, HACCP and catering <br />equipment from the Health Distinct <br />22. No food storage or preparetion is allowed in the establishment prior the preoperational <br />inspection. No food storege or preparetion is allowed in the establishment until after <br />approval to open is granted by the Health District. <br />A preoperetional inspection ia required prior io operating permit issuance and approval to open <br />for business. At the time of inspection the constn�ction of the food service establishment must be <br />complete and all equipment must be in place and in proper operating condition. lncomplete construction <br />�J� <br />